{"id":2305,"date":"2024-06-23T06:55:22","date_gmt":"2024-06-23T06:55:22","guid":{"rendered":"https:\/\/biovanix.com\/?page_id=2305"},"modified":"2024-10-08T13:36:37","modified_gmt":"2024-10-08T13:36:37","slug":"super-polymer-microspher","status":"publish","type":"page","link":"https:\/\/biovanix.com\/de\/super-polymer-microspher\/","title":{"rendered":"Supermacroporous Polymer Microspher | BioVanix"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"2305\" class=\"elementor elementor-2305\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-01b3cee e-flex e-con-boxed e-con e-parent\" data-id=\"01b3cee\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a4db07e elementor-widget elementor-widget-text-editor\" data-id=\"a4db07e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h1><span style=\"color: #ffffff;\">Supermacroporous Polymer Microspher<\/span><\/h1>\n<p><span style=\"color: #ffffff;\">In order to address key issues in the purification of viruses and viral particles, Biovanix has always been bold in its exploration of process technology and product development. Its research and production of super macroporous ion exchange chromatography media have achieved precise control over the pore size of the chromatography media. Compared to conventional chromatography media, it has better performance in terms of load capacity and processing speed. It is more conducive to maintaining the structure of viral vectors and viral-like particles.<\/span><\/p>\n<p><span style=\"color: #ffffff;\"><strong>Vorteile<\/strong><\/span><\/p>\n<ul>\n<li><span style=\"color: #ffffff;\">Large molecules or viral particles can easily enter the pores for binding;<\/span><\/li>\n<li><span style=\"color: #ffffff;\">The load capacity is more than 10 times that of conventional agarose media and<\/span><br \/><span style=\"color: #ffffff;\">twice that of conventional polymer media;<\/span><\/li>\n<li><span style=\"color: #ffffff;\">It can maintain the integrity of the structure of large molecular proteins, obtaining high yield and high activity of the target protein;<\/span><\/li>\n<li><span style=\"color: #ffffff;\">After hydrophilic modification of the microsphere surface and the bonding of ion exchange groups, non-specific adsorption is low, and the degree of mechanization is high;<\/span><\/li>\n<li><span style=\"color: #ffffff;\">The molecular mass transfer rate is fast, and better separation can be achieved<\/span><br \/><span style=\"color: #ffffff;\">at higher flow rates.<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c46ee4c e-flex e-con-boxed e-con e-parent\" data-id=\"c46ee4c\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-bd56cc7 e-con-full e-flex e-con e-child\" data-id=\"bd56cc7\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-73eadc9 elementor-widget elementor-widget-text-editor\" data-id=\"73eadc9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Polymer Products<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5586be0 e-con-full e-flex e-con e-child\" data-id=\"5586be0\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-aceba1a elementor-widget elementor-widget-image\" data-id=\"aceba1a\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"300\" height=\"225\" src=\"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/09\/GALAK-VirCap-perfuion-chromatography-media-1-300x225.webp\" class=\"attachment-medium size-medium wp-image-2462\" alt=\"\" srcset=\"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/09\/GALAK-VirCap-perfuion-chromatography-media-1-300x225.webp 300w, https:\/\/biovanix.com\/wp-content\/uploads\/2024\/09\/GALAK-VirCap-perfuion-chromatography-media-1-768x576.webp 768w, https:\/\/biovanix.com\/wp-content\/uploads\/2024\/09\/GALAK-VirCap-perfuion-chromatography-media-1-600x450.webp 600w, https:\/\/biovanix.com\/wp-content\/uploads\/2024\/09\/GALAK-VirCap-perfuion-chromatography-media-1.webp 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"Biovanix particles | BioVanix\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3beb31 elementor-widget elementor-widget-text-editor\" data-id=\"c3beb31\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h4 style=\"text-align: center;\"><a title=\"Chromatography PSDVB Microspher | BioVanix\" href=\"https:\/\/biovanix.com\/de\/psdvb-chromatography\/\">PSDVB Microsphere<\/a><\/h4>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-720b0b3 e-con-full e-flex e-con e-child\" data-id=\"720b0b3\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a68aaa6 elementor-widget elementor-widget-image\" data-id=\"a68aaa6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"300\" height=\"225\" src=\"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/09\/GALAK-VirCap-perfuion-chromatography-media-1-300x225.webp\" class=\"attachment-medium size-medium wp-image-2462\" alt=\"\" srcset=\"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/09\/GALAK-VirCap-perfuion-chromatography-media-1-300x225.webp 300w, https:\/\/biovanix.com\/wp-content\/uploads\/2024\/09\/GALAK-VirCap-perfuion-chromatography-media-1-768x576.webp 768w, https:\/\/biovanix.com\/wp-content\/uploads\/2024\/09\/GALAK-VirCap-perfuion-chromatography-media-1-600x450.webp 600w, https:\/\/biovanix.com\/wp-content\/uploads\/2024\/09\/GALAK-VirCap-perfuion-chromatography-media-1.webp 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" title=\"Biovanix particles | BioVanix\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-92e9ef8 elementor-widget elementor-widget-text-editor\" data-id=\"92e9ef8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h4 style=\"text-align: center;\"><a title=\"Chromatography PMMA Microsphere\" href=\"https:\/\/biovanix.com\/de\/pmma-chromatography\/\">PMMA-Mikrokugeln<\/a><\/h4>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4919d360 e-flex e-con-boxed e-con e-parent\" data-id=\"4919d360\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7459dea2 elementor-widget elementor-widget-text-editor\" data-id=\"7459dea2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\n<h2 style=\"text-align: center;\"><span style=\"color: #33615a;\">Microsphere Selection<\/span><\/h2>\n<h3>PS-DVB Particle Selection<\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"124\">Produkt<\/td>\n<td width=\"125\">Poly15 SP<\/td>\n<td width=\"125\">Poly15 Q<\/td>\n<td width=\"125\">Poly30 SP<\/td>\n<td width=\"124\">Poly30 Q<\/td>\n<\/tr>\n<tr>\n<td width=\"124\">Matrix<\/td>\n<td colspan=\"4\" width=\"498\">Monodisperse PS-DVB<\/td>\n<\/tr>\n<tr>\n<td width=\"124\">Partikelgr\u00f6\u00dfe<\/td>\n<td colspan=\"2\" width=\"249\">15um<\/td>\n<td colspan=\"2\" width=\"249\">30um<\/td>\n<\/tr>\n<tr>\n<td width=\"124\">Function Group<\/td>\n<td width=\"125\">(-CH2)SO3-<\/td>\n<td width=\"125\">-CH2N<sup>+<\/sup>(CH3)3<\/td>\n<td width=\"125\">(-CH2)SO3-<\/td>\n<td width=\"124\">-CH2N<sup>+<\/sup>(CH3)3<\/td>\n<\/tr>\n<tr>\n<td width=\"124\">Ligandenkonzentration<\/td>\n<td width=\"125\">0.22meq\/mL<\/td>\n<td width=\"125\">0.24meq\/mL<\/td>\n<td width=\"125\">0.15meq\/mL<\/td>\n<td width=\"124\">0.18meq\/mL<\/td>\n<\/tr>\n<tr>\n<td width=\"124\">Kapazit\u00e4t<\/td>\n<td width=\"125\">80mg Lys\/mL<\/td>\n<td width=\"125\">45mg BSA\/mL<\/td>\n<td width=\"125\">60mg Lys\/mL<\/td>\n<td width=\"124\">30mg BSA\/mL<\/td>\n<\/tr>\n<tr>\n<td width=\"124\">Durchflussmenge<\/td>\n<td colspan=\"2\" width=\"249\">150~800cm\/h<\/td>\n<td colspan=\"2\" width=\"249\">250~1000cm\/h<\/td>\n<\/tr>\n<tr>\n<td width=\"124\">Max. Druck<\/td>\n<td colspan=\"2\" width=\"249\">8.0MPa<\/td>\n<td colspan=\"2\" width=\"249\">5.0MPa<\/td>\n<\/tr>\n<tr>\n<td width=\"124\">pH Stability<\/td>\n<td colspan=\"4\" width=\"498\">2-12<\/td>\n<\/tr>\n<tr>\n<td width=\"124\">\u00a0 Chemische Best\u00e4ndigkeit<\/td>\n<td colspan=\"4\" width=\"498\">All commonly used buffers,1M acetic acid,1M sodium oxychloride, 1M hydrochloric acid, 70% ethanol 30% isopropyl alcohol, 30% acetonitrile, 1%SDS, 6M guanidine hydrochloride, 8M urea, and other commonly used organic solvents; Avoid exposure to strong oxidants.<\/td>\n<\/tr>\n<tr>\n<td width=\"124\">Usage Temperature<\/td>\n<td colspan=\"4\" width=\"498\">4~30\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"124\">Lagerung<\/td>\n<td colspan=\"4\" width=\"498\">2~30\u00b0C, 20% ethanol<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"16%\">Produkt<\/td>\n<td colspan=\"4\" width=\"83%\">Poly 50M<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Matrix<\/td>\n<td width=\"22%\">SP<\/td>\n<td width=\"22%\">Q<\/td>\n<td width=\"20%\">CM<\/td>\n<td width=\"17%\">DEAE<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Partikelgr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">PS-DVB<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Function Group<\/td>\n<td colspan=\"4\" width=\"83%\">50um<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Porengr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">100-150nm<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Ligandenkonzentration<\/td>\n<td width=\"22%\">0.15meq\/mL<\/td>\n<td width=\"22%\">0.16meq\/mL<\/td>\n<td width=\"20%\">0.15me q\/mL<\/td>\n<td width=\"17%\">0.16me q\/mL<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Kapazit\u00e4t<\/td>\n<td width=\"22%\">&gt;80mgLys<\/td>\n<td width=\"22%\">&gt;100mg BSA<\/td>\n<td width=\"20%\">&gt;80mgLys<\/td>\n<td width=\"17%\">&gt;90mg BSA<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Durchflussmenge<\/td>\n<td colspan=\"4\" width=\"83%\">300~1200cm\/h<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Max Pressure<\/td>\n<td colspan=\"4\" width=\"83%\">3.0MPa<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">pH Stability<\/td>\n<td colspan=\"4\" width=\"83%\">1-12<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Chemische Best\u00e4ndigkeit<\/td>\n<td colspan=\"4\" width=\"83%\">All commonly used buffers, 1M acetic acid, 1M sodium oxychloride, 1M hydrochloric acid, 70% ethanol 30% isopropyl alcohol, 30% acetonitrile, 1%SDS, 6M guanidine hydrochloride, 8M urea and other commonly used organic solvents; Avoid exposure to strong oxidants.<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Usage Temperature<\/td>\n<td colspan=\"4\" width=\"83%\">4~30\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Lagerung<\/td>\n<td colspan=\"4\" width=\"83%\">2~30\u00b0C, 20% ethanol<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"16%\">Produkt<\/td>\n<td colspan=\"4\" width=\"83%\">Poly 50G<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Matrix<\/td>\n<td width=\"22%\">SP<\/td>\n<td width=\"22%\">SP<\/td>\n<td width=\"20%\">SP<\/td>\n<td width=\"17%\">SP<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Partikelgr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">PS-DVB<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Function Group<\/td>\n<td colspan=\"4\" width=\"83%\">50um<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Porengr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">150-300nm<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Ligandenkonzentration<\/td>\n<td width=\"22%\">0.14me q\/mL<\/td>\n<td width=\"22%\">0.14me q\/mL<\/td>\n<td width=\"20%\">0.14me q\/mL<\/td>\n<td width=\"17%\">0.14me q\/mL<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Kapazit\u00e4t<\/td>\n<td width=\"22%\">&gt;70mg Lys<\/td>\n<td width=\"22%\">&gt;70mg Lys<\/td>\n<td width=\"20%\">&gt;70mg Lys<\/td>\n<td width=\"17%\">&gt;70mg Lys<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Durchflussmenge<\/td>\n<td colspan=\"4\" width=\"83%\">300~1200cm\/h<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Max Pressure<\/td>\n<td colspan=\"4\" width=\"83%\">2.0MPa<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">pH Stability<\/td>\n<td colspan=\"4\" width=\"83%\">1-12<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Chemische Best\u00e4ndigkeit<\/td>\n<td colspan=\"4\" width=\"83%\">All commonly used buffers, 1M acetic acid, 1M sodium oxychloride, 1M hydrochloric acid, 70% ethanol 30% isopropyl alcohol, 30% acetonitrile, 1%SDS, 6M guanidine hydrochloride, 8M urea and other commonly used organic solvents; Avoid exposure to strong oxidants.<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Usage Temperature<\/td>\n<td colspan=\"4\" width=\"83%\">4~30\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Lagerung<\/td>\n<td colspan=\"4\" width=\"83%\">2~30\u00b0C, 20% ethanol<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"16%\">Produkt<\/td>\n<td colspan=\"4\" width=\"83%\">Poly 50V<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Matrix<\/td>\n<td width=\"22%\">SP<\/td>\n<td width=\"22%\">SP<\/td>\n<td width=\"20%\">SP<\/td>\n<td width=\"17%\">SP<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Partikelgr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">PS-DVB<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Function Group<\/td>\n<td colspan=\"4\" width=\"83%\">50um<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Porengr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">300-400nm<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Ligandenkonzentration<\/td>\n<td width=\"22%\">0.12me q\/mL<\/td>\n<td width=\"22%\">0.12me q\/mL<\/td>\n<td width=\"20%\">0.12me q\/mL<\/td>\n<td width=\"17%\">0.12me q\/mL<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Kapazit\u00e4t<\/td>\n<td width=\"22%\">&gt;70mg Lys<\/td>\n<td width=\"22%\">&gt;70mg Lys<\/td>\n<td width=\"20%\">&gt;70mg Lys<\/td>\n<td width=\"17%\">&gt;70mg Lys<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Durchflussmenge<\/td>\n<td colspan=\"4\" width=\"83%\">300~1200cm\/h<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Max Pressure<\/td>\n<td colspan=\"4\" width=\"83%\">1.0MPa<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">pH Stability<\/td>\n<td colspan=\"4\" width=\"83%\">1-12<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Chemische Best\u00e4ndigkeit<\/td>\n<td colspan=\"4\" width=\"83%\">All commonly used buffers, 1M acetic acid, 1M sodium oxychloride, 1M hydrochloric acid, 70% ethanol 30% isopropyl alcohol, 30% acetonitrile, 1%SDS, 6M guanidine hydrochloride, 8M urea and other commonly used organic solvents; Avoid exposure to strong oxidants.<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Usage Temperature<\/td>\n<td colspan=\"4\" width=\"83%\">4~30\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Lagerung<\/td>\n<td colspan=\"4\" width=\"83%\">2~30\u00b0C, 20% ethanol<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PMMA Particle Selection<\/h3>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"16%\"><strong>Produkt<\/strong><\/td>\n<td colspan=\"4\" width=\"83%\"><strong>PM 70S<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Matrix<\/td>\n<td width=\"22%\">SP<\/td>\n<td width=\"22%\">Q<\/td>\n<td width=\"20%\">CM<\/td>\n<td width=\"17%\">DEAE<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Partikelgr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">PMMA<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Function Group<\/td>\n<td colspan=\"4\" width=\"83%\">70um<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Porengr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">100nm<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Ligandenkonzentration<\/td>\n<td width=\"22%\">0.18 meq\/mL<\/td>\n<td width=\"22%\">0.12meq\/mL<\/td>\n<td width=\"20%\">0.21meq\/mL<\/td>\n<td width=\"17%\">0.15meq\/mL<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Kapazit\u00e4t<\/td>\n<td width=\"22%\">115 mg Lys<\/td>\n<td width=\"22%\">80mg BSA<\/td>\n<td width=\"20%\">105 mg Lys<\/td>\n<td width=\"17%\">80mg BSA<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Durchflussmenge<\/td>\n<td colspan=\"4\" width=\"83%\">150~750cm\/h<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Max Pressure<\/td>\n<td colspan=\"4\" width=\"83%\">1.0MPa<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">pH Stability<\/td>\n<td colspan=\"4\" width=\"83%\">2-12<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Chemische Best\u00e4ndigkeit<\/td>\n<td colspan=\"4\" width=\"83%\">All commonly used buffers, 1M acetic acid, 1M sodium oxychloride, 1M hydrochloric acid, 70% ethanol 30% isopropyl alcohol, 30% acetonitrile, 1%SDS, 6M guanidine hydrochloride, 8M urea and other commonly used organic solvents; Avoid exposure to strong oxidants.<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Usage Temperature<\/td>\n<td colspan=\"4\" width=\"83%\">4~30\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Lagerung<\/td>\n<td colspan=\"4\" width=\"83%\">2~30\u00b0C, 20% ethanol<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"16%\"><strong>Produkt<\/strong><\/td>\n<td colspan=\"4\" width=\"83%\"><strong>PM 70M<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Matrix<\/td>\n<td width=\"22%\">SP<\/td>\n<td width=\"22%\">Q<\/td>\n<td width=\"20%\">CM<\/td>\n<td width=\"17%\">DEAE<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Partikelgr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">PMMA<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Function Group<\/td>\n<td colspan=\"4\" width=\"83%\">70um<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Porengr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">100-150nm<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Ligandenkonzentration<\/td>\n<td width=\"22%\">0.15meq\/mL<\/td>\n<td width=\"22%\">0.12m eq\/mL<\/td>\n<td width=\"20%\">0.22meq\/ mL<\/td>\n<td width=\"17%\">0.11meq\/mL<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Kapazit\u00e4t<\/td>\n<td width=\"22%\">115 mg Lys<\/td>\n<td width=\"22%\">80m g BSA<\/td>\n<td width=\"20%\">105mg Lys<\/td>\n<td width=\"17%\">80mg BSA<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Durchflussmenge<\/td>\n<td colspan=\"4\" width=\"83%\">150~750cm\/h<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Max Pressure<\/td>\n<td colspan=\"4\" width=\"83%\">0.8MPa<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">pH Stability<\/td>\n<td colspan=\"4\" width=\"83%\">2-12<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Chemische Best\u00e4ndigkeit<\/td>\n<td colspan=\"4\" width=\"83%\">All commonly used buffers, 1M acetic acid, 1M sodium oxychloride, 1M hydrochloric acid, 70% ethanol 30% isopropyl alcohol, 30% acetonitrile, 1%SDS, 6M guanidine hydrochloride, 8M urea and other commonly used organic solvents; Avoid exposure to strong oxidants.<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Usage Temperature<\/td>\n<td colspan=\"4\" width=\"83%\">4~30\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Lagerung<\/td>\n<td colspan=\"4\" width=\"83%\">2~30\u00b0C, 20% ethanol<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"16%\"><strong>Produkt<\/strong><\/td>\n<td colspan=\"4\" width=\"83%\"><strong>PM 70G<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Matrix<\/td>\n<td width=\"22%\">SP<\/td>\n<td width=\"22%\">Q<\/td>\n<td width=\"20%\">CM<\/td>\n<td width=\"17%\">DEAE<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Partikelgr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">PMMA<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Function Group<\/td>\n<td colspan=\"4\" width=\"83%\">70um<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Porengr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">150-300nm<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Ligandenkonzentration<\/td>\n<td width=\"22%\">0.11meq\/mL<\/td>\n<td width=\"22%\">0.12meq\/mL<\/td>\n<td width=\"20%\">0.10meq\/mL<\/td>\n<td width=\"17%\">0.09meq\/mL<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Kapazit\u00e4t<\/td>\n<td width=\"22%\">\uff1e 70mg Lys<\/td>\n<td width=\"22%\">\uff1e 75mg BSA<\/td>\n<td width=\"20%\">\uff1e 70mg Lys<\/td>\n<td width=\"17%\">\uff1e 60mg BSA<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Durchflussmenge<\/td>\n<td colspan=\"4\" width=\"83%\">150~750cm\/h<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Max Pressure<\/td>\n<td colspan=\"4\" width=\"83%\">0.5MPa<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">pH Stability<\/td>\n<td colspan=\"4\" width=\"83%\">2-12<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Chemische Best\u00e4ndigkeit<\/td>\n<td colspan=\"4\" width=\"83%\">All commonly used buffers, 1M acetic acid, 1M sodium oxychloride, 1M hydrochloric acid, 70% ethanol 30% isopropyl alcohol,30% acetonitrile, 1%SDS, 6M guanidine hydrochloride, 8M urea and other commonly used organic solvents; Avoid exposure to strong oxidants.<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Usage Temperature<\/td>\n<td colspan=\"4\" width=\"83%\">4~30\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Lagerung<\/td>\n<td colspan=\"4\" width=\"83%\">2~30\u00b0C, 20% ethanol<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"16%\"><strong>Produkt<\/strong><\/td>\n<td colspan=\"4\" width=\"83%\"><strong>PM 70G<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Matrix<\/td>\n<td width=\"22%\">SP<\/td>\n<td width=\"22%\">Q<\/td>\n<td width=\"20%\">CM<\/td>\n<td width=\"17%\">DEAE<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Partikelgr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">PMMA<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Function Group<\/td>\n<td colspan=\"4\" width=\"83%\">70um<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Porengr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">150-300nm<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Ligandenkonzentration<\/td>\n<td width=\"22%\">0.11meq\/mL<\/td>\n<td width=\"22%\">0.12meq\/mL<\/td>\n<td width=\"20%\">0.10meq\/mL<\/td>\n<td width=\"17%\">0.09meq\/ mL<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Kapazit\u00e4t<\/td>\n<td width=\"22%\">\uff1e 70mg Lys<\/td>\n<td width=\"22%\">\uff1e 75mg BSA<\/td>\n<td width=\"20%\">\uff1e 70m g Lys<\/td>\n<td width=\"17%\">\uff1e 60mg BSA<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Durchflussmenge<\/td>\n<td colspan=\"4\" width=\"83%\">150~750cm\/h<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Max Pressure<\/td>\n<td colspan=\"4\" width=\"83%\">0.5MPa<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">pH Stability<\/td>\n<td colspan=\"4\" width=\"83%\">2-12<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Chemische Best\u00e4ndigkeit<\/td>\n<td colspan=\"4\" width=\"83%\">All commonly used buffers, 1M acetic acid, 1M sodium oxychloride, 1M hydrochloric acid, 70% ethanol 30% isopropyl alcohol,30% acetonitrile, 1%SDS, 6M guanidine hydrochloride, 8M urea and other commonly used organic solvents; Avoid exposure to strong oxidants.<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Usage Temperature<\/td>\n<td colspan=\"4\" width=\"83%\">4~30\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Lagerung<\/td>\n<td colspan=\"4\" width=\"83%\">2~30\u00b0C, 20% ethanol<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"16%\"><strong>Produkt<\/strong><\/td>\n<td colspan=\"4\" width=\"83%\"><strong>PM 70V<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Matrix<\/td>\n<td width=\"22%\">SP<\/td>\n<td width=\"22%\">Q<\/td>\n<td width=\"20%\">CM<\/td>\n<td width=\"17%\">DEAE<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Partikelgr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">PMMA<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Function Group<\/td>\n<td colspan=\"4\" width=\"83%\">70um<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Porengr\u00f6\u00dfe<\/td>\n<td colspan=\"4\" width=\"83%\">300-400nm<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Ligandenkonzentration<\/td>\n<td width=\"22%\">0.11meq\/mL<\/td>\n<td width=\"22%\">0.12meq\/mL<\/td>\n<td width=\"20%\">0.10meq\/mL<\/td>\n<td width=\"17%\">0.09meq\/ mL<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Kapazit\u00e4t<\/td>\n<td width=\"22%\">\uff1e 70mg Lys<\/td>\n<td width=\"22%\">\uff1e 75mg BSA<\/td>\n<td width=\"20%\">\uff1e 70m g Lys<\/td>\n<td width=\"17%\">\uff1e 60mg BSA<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Durchflussmenge<\/td>\n<td colspan=\"4\" width=\"83%\">150~750cm\/h<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Max Pressure<\/td>\n<td colspan=\"4\" width=\"83%\">0.5MPa<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">pH Stability<\/td>\n<td colspan=\"4\" width=\"83%\">2-12<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Chemische Best\u00e4ndigkeit<\/td>\n<td colspan=\"4\" width=\"83%\">All commonly used buffers, 1M acetic acid, 1M sodium oxychloride, 1M hydrochloric acid, 70% ethanol 30% isopropyl alcohol,30% acetonitrile, 1%SDS, 6M guanidine hydrochloride, 8M urea and other commonly used organic solvents; Avoid exposure to strong oxidants.<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Usage Temperature<\/td>\n<td colspan=\"4\" width=\"83%\">4~30\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"16%\">Lagerung<\/td>\n<td colspan=\"4\" width=\"83%\">2~30\u00b0C, 20% ethanol<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2306f6cc e-flex e-con-boxed e-con e-parent\" data-id=\"2306f6cc\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-71c75503 e-con-full e-flex e-con e-child\" data-id=\"71c75503\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6fff9c66 elementor-widget elementor-widget-text-editor\" data-id=\"6fff9c66\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3><span style=\"color: #ffffff;\">Finden Sie das gew\u00fcnschte Produkt nicht? Kontaktieren Sie uns direkt.<\/span><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-722039a8 e-con-full e-flex e-con e-child\" data-id=\"722039a8\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6a1c214e elementor-align-center elementor-widget elementor-widget-button\" data-id=\"6a1c214e\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-size-sm\" role=\"button\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t<span class=\"elementor-button-icon\">\n\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-far-comment\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 32C114.6 32 0 125.1 0 240c0 47.6 19.9 91.2 52.9 126.3C38 405.7 7 439.1 6.5 439.5c-6.6 7-8.4 17.2-4.6 26S14.4 480 24 480c61.5 0 110-25.7 139.1-46.3C192 442.8 223.2 448 256 448c141.4 0 256-93.1 256-208S397.4 32 256 32zm0 368c-26.7 0-53.1-4.1-78.4-12.1l-22.7-7.2-19.5 13.8c-14.3 10.1-33.9 21.4-57.5 29 7.3-12.1 14.4-25.7 19.9-40.2l10.6-28.1-20.6-21.8C69.7 314.1 48 282.2 48 240c0-88.2 93.3-160 208-160s208 71.8 208 160-93.3 160-208 160z\"><\/path><\/svg>\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kontakt<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Supermacroporous Polymer Microspher In order to address key issues in the purification of viruses and viral particles, Biovanix has always been bold in its exploration of process technology and product development. Its research and production of super macroporous ion exchange chromatography media have achieved precise control over the pore size of the chromatography media. Compared [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_uag_custom_page_level_css":"","_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-2305","page","type-page","status-publish","hentry"],"aioseo_notices":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false,"woocommerce_thumbnail":false,"woocommerce_single":false,"woocommerce_gallery_thumbnail":false},"uagb_author_info":{"display_name":"biovanix.com","author_link":"https:\/\/biovanix.com\/de\/author\/biovanix-com\/"},"uagb_comment_info":0,"uagb_excerpt":"Supermacroporous Polymer Microspher In order to address key issues in the purification of viruses and viral particles, Biovanix has always been bold in its exploration of process technology and product development. Its research and production of super macroporous ion exchange chromatography media have achieved precise control over the pore size of the chromatography media. Compared&hellip;","aioseo_head":"\n\t\t<!-- All in One SEO Pro 4.9.3 - aioseo.com -->\n\t<meta name=\"description\" content=\"Supermacroporous polymer microsphere with PSDVB and PMMA particles for liquid chromatography.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/biovanix.com\/de\/super-polymer-microspher\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 4.9.3\" \/>\n\t\t<meta property=\"og:locale\" content=\"de_DE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"BioVanix | Professional Instrument Supplier\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Supermacroporous Polymer Microspher | BioVanix\" \/>\n\t\t<meta property=\"og:description\" content=\"Supermacroporous polymer microsphere with PSDVB and PMMA particles for liquid chromatography.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/biovanix.com\/de\/super-polymer-microspher\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"240\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2024-06-23T06:55:22+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2024-10-08T13:36:37+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/facebook.com\/BioVanix\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@BioVanix\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Supermacroporous Polymer Microspher | BioVanix\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Supermacroporous polymer microsphere with PSDVB and PMMA particles for liquid chromatography.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@BioVanix\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/de\\\/super-polymer-microspher\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/de#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/biovanix.com\\\/de\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/de\\\/super-polymer-microspher\\\/#listItem\",\"name\":\"Supermacroporous Polymer Microspher | BioVanix\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/de\\\/super-polymer-microspher\\\/#listItem\",\"position\":2,\"name\":\"Supermacroporous Polymer Microspher | BioVanix\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/de#listItem\",\"name\":\"Home\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/de\\\/#organization\",\"name\":\"biovanix.com\",\"description\":\"Professional Instrument Supplier\",\"url\":\"https:\\\/\\\/biovanix.com\\\/de\\\/\",\"telephone\":\"+8618816200534\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/biovanix.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/biovanix-logo-small.png\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/de\\\/super-polymer-microspher\\\/#organizationLogo\",\"width\":300,\"height\":240,\"caption\":\"biovanix logo small\"},\"image\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/de\\\/super-polymer-microspher\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/facebook.com\\\/BioVanix\",\"https:\\\/\\\/x.com\\\/BioVanix\",\"https:\\\/\\\/instagram.com\\\/BioVanix\",\"https:\\\/\\\/tiktok.com\\\/@BioVanix\",\"https:\\\/\\\/pinterest.com\\\/BioVanix\",\"https:\\\/\\\/youtube.com\\\/BioVanix\",\"https:\\\/\\\/linkedin.com\\\/in\\\/BioVanix\"]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/de\\\/super-polymer-microspher\\\/#webpage\",\"url\":\"https:\\\/\\\/biovanix.com\\\/de\\\/super-polymer-microspher\\\/\",\"name\":\"Supermacroporous Polymer Microspher | BioVanix\",\"description\":\"Supermacroporous polymer microsphere with PSDVB and PMMA particles for liquid chromatography.\",\"inLanguage\":\"de-DE-formal\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/de\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/de\\\/super-polymer-microspher\\\/#breadcrumblist\"},\"datePublished\":\"2024-06-23T06:55:22+08:00\",\"dateModified\":\"2024-10-08T13:36:37+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/biovanix.com\\\/de\\\/\",\"name\":\"biovanix.com\",\"description\":\"Professional Instrument Supplier\",\"inLanguage\":\"de-DE-formal\",\"publisher\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/de\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Supermacroporous Polymer Microspher | BioVanix<\/title>\n\n","aioseo_head_json":{"title":"Supermacroporous Polymer Microspher | BioVanix","description":"Supermacroporous polymer microsphere with PSDVB and PMMA particles for liquid chromatography.","canonical_url":"https:\/\/biovanix.com\/de\/super-polymer-microspher\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/biovanix.com\/de\/super-polymer-microspher\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/biovanix.com\/de#listItem","position":1,"name":"Home","item":"https:\/\/biovanix.com\/de","nextItem":{"@type":"ListItem","@id":"https:\/\/biovanix.com\/de\/super-polymer-microspher\/#listItem","name":"Supermacroporous Polymer Microspher | BioVanix"}},{"@type":"ListItem","@id":"https:\/\/biovanix.com\/de\/super-polymer-microspher\/#listItem","position":2,"name":"Supermacroporous Polymer Microspher | BioVanix","previousItem":{"@type":"ListItem","@id":"https:\/\/biovanix.com\/de#listItem","name":"Home"}}]},{"@type":"Organization","@id":"https:\/\/biovanix.com\/de\/#organization","name":"biovanix.com","description":"Professional Instrument Supplier","url":"https:\/\/biovanix.com\/de\/","telephone":"+8618816200534","logo":{"@type":"ImageObject","url":"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png","@id":"https:\/\/biovanix.com\/de\/super-polymer-microspher\/#organizationLogo","width":300,"height":240,"caption":"biovanix logo small"},"image":{"@id":"https:\/\/biovanix.com\/de\/super-polymer-microspher\/#organizationLogo"},"sameAs":["https:\/\/facebook.com\/BioVanix","https:\/\/x.com\/BioVanix","https:\/\/instagram.com\/BioVanix","https:\/\/tiktok.com\/@BioVanix","https:\/\/pinterest.com\/BioVanix","https:\/\/youtube.com\/BioVanix","https:\/\/linkedin.com\/in\/BioVanix"]},{"@type":"WebPage","@id":"https:\/\/biovanix.com\/de\/super-polymer-microspher\/#webpage","url":"https:\/\/biovanix.com\/de\/super-polymer-microspher\/","name":"Supermacroporous Polymer Microspher | BioVanix","description":"Supermacroporous polymer microsphere with PSDVB and PMMA particles for liquid chromatography.","inLanguage":"de-DE-formal","isPartOf":{"@id":"https:\/\/biovanix.com\/de\/#website"},"breadcrumb":{"@id":"https:\/\/biovanix.com\/de\/super-polymer-microspher\/#breadcrumblist"},"datePublished":"2024-06-23T06:55:22+08:00","dateModified":"2024-10-08T13:36:37+08:00"},{"@type":"WebSite","@id":"https:\/\/biovanix.com\/de\/#website","url":"https:\/\/biovanix.com\/de\/","name":"biovanix.com","description":"Professional Instrument Supplier","inLanguage":"de-DE-formal","publisher":{"@id":"https:\/\/biovanix.com\/de\/#organization"}}]},"og:locale":"de_DE","og:site_name":"BioVanix | Professional Instrument Supplier","og:type":"article","og:title":"Supermacroporous Polymer Microspher | BioVanix","og:description":"Supermacroporous polymer microsphere with PSDVB and PMMA particles for liquid chromatography.","og:url":"https:\/\/biovanix.com\/de\/super-polymer-microspher\/","og:image":"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png","og:image:secure_url":"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png","og:image:width":300,"og:image:height":240,"article:published_time":"2024-06-23T06:55:22+00:00","article:modified_time":"2024-10-08T13:36:37+00:00","article:publisher":"https:\/\/facebook.com\/BioVanix","twitter:card":"summary_large_image","twitter:site":"@BioVanix","twitter:title":"Supermacroporous Polymer Microspher | BioVanix","twitter:description":"Supermacroporous polymer microsphere with PSDVB and PMMA particles for liquid chromatography.","twitter:creator":"@BioVanix","twitter:image":"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png"},"aioseo_meta_data":{"post_id":"2305","title":"Supermacroporous Polymer Microspher | BioVanix","description":"Supermacroporous polymer microsphere with PSDVB and PMMA particles for liquid chromatography.","keywords":null,"keyphrases":{"focus":{"keyphrase":"PSDVB","score":46,"analysis":{"keyphraseInTitle":{"score":3,"maxScore":9,"error":1},"keyphraseInDescription":{"score":9,"maxScore":9,"error":0},"keyphraseLength":{"score":9,"maxScore":9,"error":0,"length":1},"keyphraseInURL":{"score":1,"maxScore":5,"error":1},"keyphraseInIntroduction":{"score":3,"maxScore":9,"error":1},"keyphraseInSubHeadings":{"score":3,"maxScore":9,"error":1},"keyphraseInImageAlt":{"score":3,"maxScore":9,"error":1},"keywordDensity":{"score":0,"type":"low","maxScore":9,"error":1}}},"additional":[{"keyphrase":"PMMA","score":73,"analysis":{"keyphraseInDescription":{"score":9,"maxScore":9,"error":0},"keyphraseLength":{"score":9,"maxScore":9,"error":0,"length":1},"keyphraseInIntroduction":{"score":3,"maxScore":9,"error":1},"keyphraseInImageAlt":{"score":3,"maxScore":9,"error":1},"keywordDensity":{"type":"best","score":9,"maxScore":9,"error":0}}}]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"WebPage","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2025-08-22 09:35:58","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":"{\"title\":{\"suggestions\":[],\"usage\":0},\"description\":{\"suggestions\":[],\"usage\":0}}","ai":null,"created":"2024-06-23 06:29:10","updated":"2025-08-22 09:35:58"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/biovanix.com\/de\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\tSupermacroporous Polymer Microspher | BioVanix\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/biovanix.com\/de"},{"label":"Supermacroporous Polymer Microspher | BioVanix","link":"https:\/\/biovanix.com\/de\/super-polymer-microspher\/"}],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/biovanix.com\/de\/wp-json\/wp\/v2\/pages\/2305","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/biovanix.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/biovanix.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/biovanix.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/biovanix.com\/de\/wp-json\/wp\/v2\/comments?post=2305"}],"version-history":[{"count":15,"href":"https:\/\/biovanix.com\/de\/wp-json\/wp\/v2\/pages\/2305\/revisions"}],"predecessor-version":[{"id":4293,"href":"https:\/\/biovanix.com\/de\/wp-json\/wp\/v2\/pages\/2305\/revisions\/4293"}],"wp:attachment":[{"href":"https:\/\/biovanix.com\/de\/wp-json\/wp\/v2\/media?parent=2305"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}