{"id":4179,"date":"2025-01-31T03:56:41","date_gmt":"2025-01-31T03:56:41","guid":{"rendered":"https:\/\/biovanix.com\/?p=4179"},"modified":"2025-02-02T04:59:29","modified_gmt":"2025-02-02T04:59:29","slug":"the-selection-for-usp-us-pharmacopeia-column","status":"publish","type":"post","link":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/","title":{"rendered":"Selecci\u00f3n para la columna USP (US Pharmacopeia)"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4179\" class=\"elementor elementor-4179\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-19bb127 e-flex e-con-boxed e-con e-parent\" data-id=\"19bb127\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-47dbee9 e-con-full e-flex e-con e-child\" data-id=\"47dbee9\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4b26f83 elementor-widget elementor-widget-text-editor\" data-id=\"4b26f83\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h1><span style=\"color: #ffffff;\">The Selection of HPLC Column By USP<\/span><\/h1><p>Las columnas USP (United States Pharmacopeia) son columnas de cromatograf\u00eda l\u00edquida de alto rendimiento (HPLC) dise\u00f1adas para cumplir las estrictas normas establecidas por la USP, lo que garantiza la coherencia, la fiabilidad y el cumplimiento de los procedimientos anal\u00edticos. Estas columnas se utilizan ampliamente en aplicaciones farmac\u00e9uticas, medioambientales y de seguridad alimentaria para proporcionar resultados precisos y reproducibles.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e6ac157 e-con-full e-flex e-con e-child\" data-id=\"e6ac157\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1df782f elementor-widget elementor-widget-image\" data-id=\"1df782f\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/05\/Biovanix-Ion-exchange-HPLC-Column.jpg\" class=\"attachment-large size-large wp-image-2202\" alt=\"\" srcset=\"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/05\/Biovanix-Ion-exchange-HPLC-Column.jpg 500w, https:\/\/biovanix.com\/wp-content\/uploads\/2024\/05\/Biovanix-Ion-exchange-HPLC-Column-300x300.jpg 300w, https:\/\/biovanix.com\/wp-content\/uploads\/2024\/05\/Biovanix-Ion-exchange-HPLC-Column-150x150.jpg 150w, https:\/\/biovanix.com\/wp-content\/uploads\/2024\/05\/Biovanix-Ion-exchange-HPLC-Column-100x100.jpg 100w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b1b2d8 e-flex e-con-boxed e-con e-parent\" data-id=\"1b1b2d8\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-383ffd4 elementor-widget elementor-widget-text-editor\" data-id=\"383ffd4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Key Feature of USP Column<\/h3><ul><li><div class=\"paragraph\"><strong class=\"\">Standardized Classification<\/strong>: USP columns are categorized based on their stationary phase characteristics, each assigned a specific &#8220;L&#8221; number. This classification helps users quickly identify the appropriate column for their specific analytical needs.<\/div><\/li><li><div class=\"paragraph\"><strong>Wide Range of Applications<\/strong>: USP columns cover a broad range of chemistries, including C18 (L1), C8 (L7), NH\u2082 (L8), CN (L10), and many others. These columns are suitable for analyzing a variety of compounds, from small molecules to complex mixtures.<\/div><\/li><li><div class=\"paragraph\"><strong class=\"\">High Quality and Compliance<\/strong>: Each USP column is manufactured to meet the exact specifications outlined by the USP, ensuring high performance and reliability in regulated environments.<\/div><\/li><li><div class=\"paragraph\"><strong>Versatile Options<\/strong>: Available in various particle sizes and formats (e.g., fully porous, fused-core, monolithic), USP columns can be tailored to meet diverse analytical requirements.<\/div><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a8b9b0 elementor-widget elementor-widget-text-editor\" data-id=\"0a8b9b0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Application of USP Column<\/h3><p>\u00a0<\/p><ul><li><div class=\"paragraph\"><strong class=\"\">Pharmaceutical Analysis<\/strong>: USP columns are extensively used in the pharmaceutical industry for the separation and quantification of active pharmaceutical ingredients (APIs), impurities, and degradation products. For example, L1 (C18) columns are commonly used for reversed-phase HPLC analysis.<\/div><\/li><li><div class=\"paragraph\"><strong>Vigilancia medioambiental<\/strong>: These columns are employed to detect and quantify pollutants and contaminants in water and soil samples. Specific chemistries like CN (L10) and NH\u2082 (L8) are useful for analyzing polar compounds.<\/div><\/li><li><div class=\"paragraph\"><strong class=\"\">Food Safety<\/strong>: USP columns help in the analysis of food additives, contaminants, and nutritional components, ensuring compliance with food safety regulations<\/div><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c1ab90a e-flex e-con-boxed e-con e-parent\" data-id=\"c1ab90a\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-92b2af2 elementor-widget elementor-widget-text-editor\" data-id=\"92b2af2\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table style=\"font-size: 16px; font-style: normal;\"><tbody><tr><td width=\"79\"><strong>Listado USP<\/strong><\/td><td width=\"485\"><strong>Descripci\u00f3n<\/strong><\/td><td width=\"123\"><strong>Productos<\/strong><\/td><\/tr><tr><td width=\"79\">L1<\/td><td width=\"485\">Octadecyl silane chemically bonded to porous or non-porous silica or ceramic microparticles, 1.5 to 10 \u00b5m in diameter, or a monolithic rod<\/td><td width=\"123\"><a title=\"Columna HPLC de gel de s\u00edlice empaquetada C18 | BioVanix Chromatography\" href=\"https:\/\/biovanix.com\/es\/c18-hplc-column\/\">C18\/ODS<\/a><\/td><\/tr><tr><td width=\"79\">L3<\/td><td width=\"485\">Porous silica particles, 1.5 to 10 \u00b5m in diameter, or a monolithic silica rod<\/td><td width=\"123\"><a title=\"Columna SiO2 para HPLC | BioVanix Technology\" href=\"https:\/\/biovanix.com\/es\/columna-sio2-hplc\/\">Silica<\/a><\/td><\/tr><tr><td width=\"79\">L7<\/td><td width=\"485\">Octylsilane chemically bonded to totally or super\ufb01cially porous silica particles, 1.5 to 10 \u00b5m in\u00a0diameter, or a monolithic silica rod<\/td><td width=\"123\"><a title=\"C8 HPLC Columna de gel de s\u00edlice empaquetada | BioVanix Technology\" href=\"https:\/\/biovanix.com\/es\/columna-c8\/\">C8<\/a><\/td><\/tr><tr><td width=\"79\">L8<\/td><td width=\"485\">An essentially monomolecular layer of aminopropylsilane chemically bonded to totally porous silica gel support, 1.5 to 10 \u00b5m in diameter, or a monolithic silica rod<\/td><td width=\"123\"><a title=\"Columna NH2\/Amino para HPLC | BioVanix Technology\" href=\"https:\/\/biovanix.com\/es\/columna-hplc-nh2\/\">NH2<\/a><\/td><\/tr><tr><td width=\"79\">L9<\/td><td width=\"485\">Irregular or spherical, totally porous silica gel having a chemically bonded, strongly acidic cation-exchange coating, 3 to 10 \u03bcm in diameter<\/td><td width=\"123\"><a title=\"Columna preempaquetada para HPLC de intercambio i\u00f3nico IEX\" href=\"https:\/\/biovanix.com\/es\/columna-preempaquetada-de-intercambio-ionico-iex-hplc\/\">SCX<\/a><\/td><\/tr><tr><td width=\"79\">L10<\/td><td width=\"485\">Nitrile groups chemically bonded to porous silica particles, 1.5 to 10 \u00b5m in diameter, or a\u00a0monolithic silica rod<\/td><td width=\"123\"><a title=\"CN\/Cyano Columna HPLC\" href=\"https:\/\/biovanix.com\/es\/product\/cyano-hplc-column\/\">CN<\/a><\/td><\/tr><tr><td width=\"79\">L11<\/td><td width=\"485\">Phenyl groups chemically bonded to porous silica particles, 1.5 to 10 \u00b5m in diameter, or a\u00a0monolithic silica rod<\/td><td width=\"123\"><a title=\"Phenyl HPLC Column\" href=\"https:\/\/biovanix.com\/es\/product\/phenyl-hplc-column\/\">Fenil<\/a><\/td><\/tr><tr><td width=\"79\">L14<\/td><td width=\"485\">Silica gel having a chemically bonded strongly basic quaternary ammonium anion-exchange coating, 5 to 10 \u00b5m in diameter<\/td><td width=\"123\"><a title=\"Columna preempaquetada para HPLC de intercambio i\u00f3nico IEX\" href=\"https:\/\/biovanix.com\/es\/columna-preempaquetada-de-intercambio-ionico-iex-hplc\/\">SAX<\/a><\/td><\/tr><tr><td width=\"79\">L17<\/td><td width=\"485\">Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the hydrogen form, 6 to 12 \u00b5m in diameter<\/td><td width=\"123\"><a title=\"Columna HPLC para an\u00e1lisis de az\u00facar | BioVanix Technology\" href=\"https:\/\/biovanix.com\/es\/sugar-analysis-column\/\">Sugar-10H<\/a><\/td><\/tr><tr><td width=\"79\">L19<\/td><td width=\"485\">Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the calcium form, 5 &#8211; 15 \u00b5m in diameter<\/td><td width=\"123\"><a title=\"Columna HPLC para an\u00e1lisis de az\u00facar | BioVanix Technology\" href=\"https:\/\/biovanix.com\/es\/sugar-analysis-column\/\">Sugar-10Ca<\/a><\/td><\/tr><tr><td width=\"79\">L20<\/td><td width=\"485\">Dihydroxypropane groups chemically bonded to porous silica or hybrid particles, 1.5 to 10 \u00b5m\u00a0in diameter, or a monolithic silica rod<\/td><td width=\"123\"><a title=\"Columna HILIC\" href=\"https:\/\/biovanix.com\/es\/columna-hilica\/\">HILIC-Diol<\/a><br \/><a title=\"Columna de relleno SEC HPLC | BioVanix Technology\" href=\"https:\/\/biovanix.com\/es\/sec-column\/\">SEC<\/a><\/td><\/tr><tr><td width=\"79\">L26<\/td><td width=\"485\">Butyl silane chemically bonded to totally porous or super\ufb01cially porous silica particles, 1.5 to 10 \u00b5m in diameter<\/td><td width=\"123\"><a title=\"C4 HPLC Columna de s\u00edlice-gel empaquetada | BioVanix Technology\" href=\"https:\/\/biovanix.com\/es\/c4-columna-hplc\/\">C4<\/a><\/td><\/tr><tr><td width=\"79\">L40<\/td><td width=\"485\">Cellulose tris-3,5-dimethylphenylcarbamate coated porous silica particles, 3 \u00b5m to 20 \u00b5m in diameter<\/td><td width=\"123\"><a title=\"Columna HPLC quiral OD OJ OZ AD AS AZ | BioVanix Technology\" href=\"https:\/\/biovanix.com\/es\/chiral-column\/\">Chiral OD<\/a><\/td><\/tr><tr><td width=\"79\">L43<\/td><td width=\"485\">Penta\ufb02uorophenyl groups chemically bonded to silica particles by a propyl spacer,\u00a01.5 to 10 \u00b5m in diameter<\/td><td width=\"123\">PFP<\/td><\/tr><tr><td width=\"79\">L51<\/td><td width=\"485\">Amylose tris-3,5-dimethylphenylcarbamate-coated, porous, spherical, silica particles, 3 to 10 \u00b5m in diameter<\/td><td width=\"123\"><a title=\"Columna HPLC quiral OD OJ OZ AD AS AZ | BioVanix Technology\" href=\"https:\/\/biovanix.com\/es\/chiral-column\/\">Chiral AD<\/a><\/td><\/tr><tr><td width=\"79\">L58<\/td><td width=\"485\">Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the sodium form, about 6 to 30 \u00b5m diameter<\/td><td width=\"123\"><a title=\"Columna HPLC para an\u00e1lisis de az\u00facar | BioVanix Technology\" href=\"https:\/\/biovanix.com\/es\/sugar-analysis-column\/\">Sugar-10Na<\/a><\/td><\/tr><tr><td width=\"79\">L60<\/td><td width=\"485\">Spherical, porous silica gel, 10 \u00b5m or less in diameter, the surface of which has been covalently modi\ufb01ed with alkyl amide groups and endcapped<\/td><td width=\"123\">Polar C18<\/td><\/tr><tr><td width=\"79\">L62<\/td><td width=\"485\">C30 silane bonded phase on a fully porous spherical silica, 3 to 15 \u00b5m in diameter<\/td><td width=\"123\">C30<\/td><\/tr><tr><td width=\"79\">L68<\/td><td width=\"485\">Spherical, porous silica, 10 \u00b5m or less in diameter, the surface of which has been covalently modi\ufb01ed with alkyl amide groups and not endcapped<\/td><td width=\"123\"><a title=\"Columna HILIC\" href=\"https:\/\/biovanix.com\/es\/columna-hilica\/\">HILIC-Amide<\/a><br \/>Glycan<\/td><\/tr><tr><td width=\"79\">L78<\/td><td width=\"485\">A silane ligand that consists of both reversed-phase (an alkyl chain longer than C8) and anion-exchange (primary, secondary, tertiary, or quartenary amino groups) functional groups chemically bonded to porous or non-porous silica or ceramic micro-particles, 1.0 to 50 \u03bcm in diameter, or a monolithic rod<\/td><td width=\"123\">SAA<\/td><\/tr><tr><td width=\"79\">L80<\/td><td width=\"485\">Cellulose tris(4-methylbenzoate)-coated, porous, spherical, silica particles, 5 &#8211; 20 \u00b5m in diameter<\/td><td width=\"123\"><a title=\"Columna HPLC quiral OD OJ OZ AD AS AZ | BioVanix Technology\" href=\"https:\/\/biovanix.com\/es\/chiral-column\/\">Chiral OJ<\/a><\/td><\/tr><tr><td width=\"79\">L90<\/td><td width=\"485\">Amylose tris-[(S)-alpha-methylbenzylcarbamate] coated on porous, spherical silica particles, 3 to 10 \u00b5m in diameter<\/td><td width=\"123\"><a title=\"Columna HPLC quiral OD OJ OZ AD AS AZ | BioVanix Technology\" href=\"https:\/\/biovanix.com\/es\/chiral-column\/\">Chiral AS<\/a><\/td><\/tr><tr><td width=\"79\">L118<\/td><td width=\"485\">Aqueous polymerized C18 groups on silica particles, 1.2 to 5 \u03bcm in diameter<\/td><td width=\"123\">PAH<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>The Selection of HPLC Column By USP USP (United States Pharmacopeia) columns are high-performance liquid chromatography (HPLC) columns designed to meet the stringent standards set by the USP, ensuring consistency, reliability, and compliance in analytical procedures. These columns are widely used in pharmaceutical, environmental, and food safety applications to provide accurate and reproducible results. Key [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_uag_custom_page_level_css":"","_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[51],"tags":[],"class_list":["post-4179","post","type-post","status-publish","format-standard","hentry","category-selection-for-chromatogrphy-column"],"aioseo_notices":[],"jetpack_featured_media_url":"","uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false,"woocommerce_thumbnail":false,"woocommerce_single":false,"woocommerce_gallery_thumbnail":false},"uagb_author_info":{"display_name":"biovanix.com","author_link":"https:\/\/biovanix.com\/es\/author\/biovanix-com\/"},"uagb_comment_info":18,"uagb_excerpt":"The Selection of HPLC Column By USP USP (United States Pharmacopeia) columns are high-performance liquid chromatography (HPLC) columns designed to meet the stringent standards set by the USP, ensuring consistency, reliability, and compliance in analytical procedures. These columns are widely used in pharmaceutical, environmental, and food safety applications to provide accurate and reproducible results. Key&hellip;","aioseo_head":"\n\t\t<!-- All in One SEO Pro 4.9.3 - aioseo.com -->\n\t<meta name=\"description\" content=\"USP columns are high-performance liquid chromatography HPLC column designed to meet the stringent standards set by the USP.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"biovanix.com\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 4.9.3\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"BioVanix | Professional Instrument Supplier\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Selection For USP (US Pharmacopeia) Column | BioVanix\" \/>\n\t\t<meta property=\"og:description\" content=\"USP columns are high-performance liquid chromatography HPLC column designed to meet the stringent standards set by the USP.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"240\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2025-01-31T03:56:41+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2025-02-02T04:59:29+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/facebook.com\/BioVanix\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@BioVanix\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Selection For USP (US Pharmacopeia) Column | BioVanix\" \/>\n\t\t<meta name=\"twitter:description\" content=\"USP columns are high-performance liquid chromatography HPLC column designed to meet the stringent standards set by the USP.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@BioVanix\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/the-selection-for-usp-us-pharmacopeia-column\\\/#blogposting\",\"name\":\"Selection For USP (US Pharmacopeia) Column | BioVanix\",\"headline\":\"Selection For USP (US Pharmacopeia) Column\",\"author\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/author\\\/biovanix-com\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/biovanix.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/Biovanix-Ion-exchange-HPLC-Column.jpg\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/the-selection-for-usp-us-pharmacopeia-column\\\/#articleImage\",\"width\":500,\"height\":500},\"datePublished\":\"2025-01-31T03:56:41+08:00\",\"dateModified\":\"2025-02-02T04:59:29+08:00\",\"inLanguage\":\"es-AR\",\"commentCount\":18,\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/the-selection-for-usp-us-pharmacopeia-column\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/the-selection-for-usp-us-pharmacopeia-column\\\/#webpage\"},\"articleSection\":\"Selection For Chromatogrphy Column\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/the-selection-for-usp-us-pharmacopeia-column\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/biovanix.com\\\/es\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/category\\\/selection-for-chromatogrphy-column\\\/#listItem\",\"name\":\"Selection For Chromatogrphy Column\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/category\\\/selection-for-chromatogrphy-column\\\/#listItem\",\"position\":2,\"name\":\"Selection For Chromatogrphy Column\",\"item\":\"https:\\\/\\\/biovanix.com\\\/es\\\/category\\\/selection-for-chromatogrphy-column\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/the-selection-for-usp-us-pharmacopeia-column\\\/#listItem\",\"name\":\"Selection For USP (US Pharmacopeia) Column\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/the-selection-for-usp-us-pharmacopeia-column\\\/#listItem\",\"position\":3,\"name\":\"Selection For USP (US Pharmacopeia) Column\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/category\\\/selection-for-chromatogrphy-column\\\/#listItem\",\"name\":\"Selection For Chromatogrphy Column\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/#organization\",\"name\":\"biovanix.com\",\"description\":\"Professional Instrument Supplier\",\"url\":\"https:\\\/\\\/biovanix.com\\\/es\\\/\",\"telephone\":\"+8618816200534\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/biovanix.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/biovanix-logo-small.png\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/the-selection-for-usp-us-pharmacopeia-column\\\/#organizationLogo\",\"width\":300,\"height\":240,\"caption\":\"biovanix logo small\"},\"image\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/the-selection-for-usp-us-pharmacopeia-column\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/facebook.com\\\/BioVanix\",\"https:\\\/\\\/x.com\\\/BioVanix\",\"https:\\\/\\\/instagram.com\\\/BioVanix\",\"https:\\\/\\\/tiktok.com\\\/@BioVanix\",\"https:\\\/\\\/pinterest.com\\\/BioVanix\",\"https:\\\/\\\/youtube.com\\\/BioVanix\",\"https:\\\/\\\/linkedin.com\\\/in\\\/BioVanix\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/author\\\/biovanix-com\\\/#author\",\"url\":\"https:\\\/\\\/biovanix.com\\\/es\\\/author\\\/biovanix-com\\\/\",\"name\":\"biovanix.com\",\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/df30e6a057e2d24641a92f2b8a2c13c57b6e85c97e467641803fe374823f04f7?s=96&d=mm&r=g\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/the-selection-for-usp-us-pharmacopeia-column\\\/#webpage\",\"url\":\"https:\\\/\\\/biovanix.com\\\/es\\\/the-selection-for-usp-us-pharmacopeia-column\\\/\",\"name\":\"Selection For USP (US Pharmacopeia) Column | BioVanix\",\"description\":\"USP columns are high-performance liquid chromatography HPLC column designed to meet the stringent standards set by the USP.\",\"inLanguage\":\"es-AR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/the-selection-for-usp-us-pharmacopeia-column\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/author\\\/biovanix-com\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/author\\\/biovanix-com\\\/#author\"},\"datePublished\":\"2025-01-31T03:56:41+08:00\",\"dateModified\":\"2025-02-02T04:59:29+08:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/biovanix.com\\\/es\\\/\",\"name\":\"biovanix.com\",\"description\":\"Professional Instrument Supplier\",\"inLanguage\":\"es-AR\",\"publisher\":{\"@id\":\"https:\\\/\\\/biovanix.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Selection For USP (US Pharmacopeia) Column | BioVanix<\/title>\n\n","aioseo_head_json":{"title":"Selection For USP (US Pharmacopeia) Column | BioVanix","description":"USP columns are high-performance liquid chromatography HPLC column designed to meet the stringent standards set by the USP.","canonical_url":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/#blogposting","name":"Selection For USP (US Pharmacopeia) Column | BioVanix","headline":"Selection For USP (US Pharmacopeia) Column","author":{"@id":"https:\/\/biovanix.com\/es\/author\/biovanix-com\/#author"},"publisher":{"@id":"https:\/\/biovanix.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/05\/Biovanix-Ion-exchange-HPLC-Column.jpg","@id":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/#articleImage","width":500,"height":500},"datePublished":"2025-01-31T03:56:41+08:00","dateModified":"2025-02-02T04:59:29+08:00","inLanguage":"es-AR","commentCount":18,"mainEntityOfPage":{"@id":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/#webpage"},"isPartOf":{"@id":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/#webpage"},"articleSection":"Selection For Chromatogrphy Column"},{"@type":"BreadcrumbList","@id":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/biovanix.com\/es#listItem","position":1,"name":"Home","item":"https:\/\/biovanix.com\/es","nextItem":{"@type":"ListItem","@id":"https:\/\/biovanix.com\/es\/category\/selection-for-chromatogrphy-column\/#listItem","name":"Selection For Chromatogrphy Column"}},{"@type":"ListItem","@id":"https:\/\/biovanix.com\/es\/category\/selection-for-chromatogrphy-column\/#listItem","position":2,"name":"Selection For Chromatogrphy Column","item":"https:\/\/biovanix.com\/es\/category\/selection-for-chromatogrphy-column\/","nextItem":{"@type":"ListItem","@id":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/#listItem","name":"Selection For USP (US Pharmacopeia) Column"},"previousItem":{"@type":"ListItem","@id":"https:\/\/biovanix.com\/es#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/#listItem","position":3,"name":"Selection For USP (US Pharmacopeia) Column","previousItem":{"@type":"ListItem","@id":"https:\/\/biovanix.com\/es\/category\/selection-for-chromatogrphy-column\/#listItem","name":"Selection For Chromatogrphy Column"}}]},{"@type":"Organization","@id":"https:\/\/biovanix.com\/es\/#organization","name":"biovanix.com","description":"Professional Instrument Supplier","url":"https:\/\/biovanix.com\/es\/","telephone":"+8618816200534","logo":{"@type":"ImageObject","url":"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png","@id":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/#organizationLogo","width":300,"height":240,"caption":"biovanix logo small"},"image":{"@id":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/#organizationLogo"},"sameAs":["https:\/\/facebook.com\/BioVanix","https:\/\/x.com\/BioVanix","https:\/\/instagram.com\/BioVanix","https:\/\/tiktok.com\/@BioVanix","https:\/\/pinterest.com\/BioVanix","https:\/\/youtube.com\/BioVanix","https:\/\/linkedin.com\/in\/BioVanix"]},{"@type":"Person","@id":"https:\/\/biovanix.com\/es\/author\/biovanix-com\/#author","url":"https:\/\/biovanix.com\/es\/author\/biovanix-com\/","name":"biovanix.com","image":{"@type":"ImageObject","url":"https:\/\/secure.gravatar.com\/avatar\/df30e6a057e2d24641a92f2b8a2c13c57b6e85c97e467641803fe374823f04f7?s=96&d=mm&r=g"}},{"@type":"WebPage","@id":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/#webpage","url":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/","name":"Selection For USP (US Pharmacopeia) Column | BioVanix","description":"USP columns are high-performance liquid chromatography HPLC column designed to meet the stringent standards set by the USP.","inLanguage":"es-AR","isPartOf":{"@id":"https:\/\/biovanix.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/#breadcrumblist"},"author":{"@id":"https:\/\/biovanix.com\/es\/author\/biovanix-com\/#author"},"creator":{"@id":"https:\/\/biovanix.com\/es\/author\/biovanix-com\/#author"},"datePublished":"2025-01-31T03:56:41+08:00","dateModified":"2025-02-02T04:59:29+08:00"},{"@type":"WebSite","@id":"https:\/\/biovanix.com\/es\/#website","url":"https:\/\/biovanix.com\/es\/","name":"biovanix.com","description":"Professional Instrument Supplier","inLanguage":"es-AR","publisher":{"@id":"https:\/\/biovanix.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"BioVanix | Professional Instrument Supplier","og:type":"article","og:title":"Selection For USP (US Pharmacopeia) Column | BioVanix","og:description":"USP columns are high-performance liquid chromatography HPLC column designed to meet the stringent standards set by the USP.","og:url":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/","og:image":"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png","og:image:secure_url":"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png","og:image:width":300,"og:image:height":240,"article:published_time":"2025-01-31T03:56:41+00:00","article:modified_time":"2025-02-02T04:59:29+00:00","article:publisher":"https:\/\/facebook.com\/BioVanix","twitter:card":"summary_large_image","twitter:site":"@BioVanix","twitter:title":"Selection For USP (US Pharmacopeia) Column | BioVanix","twitter:description":"USP columns are high-performance liquid chromatography HPLC column designed to meet the stringent standards set by the USP.","twitter:creator":"@BioVanix","twitter:image":"https:\/\/biovanix.com\/wp-content\/uploads\/2024\/01\/biovanix-logo-small.png"},"aioseo_meta_data":{"post_id":"4179","title":null,"description":"USP columns are high-performance liquid chromatography HPLC column designed to meet the stringent standards set by the USP.","keywords":null,"keyphrases":{"focus":{"keyphrase":"HPLC Column","score":46,"analysis":{"keyphraseInTitle":{"score":3,"maxScore":9,"error":1},"keyphraseInDescription":{"score":9,"maxScore":9,"error":0},"keyphraseLength":{"score":9,"maxScore":9,"error":0,"length":2},"keyphraseInURL":{"score":1,"maxScore":5,"error":1},"keyphraseInIntroduction":{"score":3,"maxScore":9,"error":1},"keyphraseInSubHeadings":{"score":3,"maxScore":9,"error":1},"keyphraseInImageAlt":{"score":3,"maxScore":9,"error":1},"keywordDensity":{"score":0,"type":"low","maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2025-08-22 09:22:17","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":"{\"title\":{\"suggestions\":[],\"usage\":0},\"description\":{\"suggestions\":[],\"usage\":0}}","ai":null,"created":"2025-01-31 03:56:41","updated":"2025-08-22 09:22:17"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/biovanix.com\/es\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/biovanix.com\/es\/category\/selection-for-chromatogrphy-column\/\" title=\"Selection For Chromatogrphy Column\">Selection For Chromatogrphy Column<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\tSelection For USP (US Pharmacopeia) Column\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/biovanix.com\/es"},{"label":"Selection For Chromatogrphy Column","link":"https:\/\/biovanix.com\/es\/category\/selection-for-chromatogrphy-column\/"},{"label":"Selection For USP (US Pharmacopeia) Column","link":"https:\/\/biovanix.com\/es\/the-selection-for-usp-us-pharmacopeia-column\/"}],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/biovanix.com\/es\/wp-json\/wp\/v2\/posts\/4179","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/biovanix.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/biovanix.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/biovanix.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/biovanix.com\/es\/wp-json\/wp\/v2\/comments?post=4179"}],"version-history":[{"count":20,"href":"https:\/\/biovanix.com\/es\/wp-json\/wp\/v2\/posts\/4179\/revisions"}],"predecessor-version":[{"id":4457,"href":"https:\/\/biovanix.com\/es\/wp-json\/wp\/v2\/posts\/4179\/revisions\/4457"}],"wp:attachment":[{"href":"https:\/\/biovanix.com\/es\/wp-json\/wp\/v2\/media?parent=4179"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/biovanix.com\/es\/wp-json\/wp\/v2\/categories?post=4179"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/biovanix.com\/es\/wp-json\/wp\/v2\/tags?post=4179"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}