UV Detector For HPLC System

Variable Dual Wavelength UV/VIS Detector

Biovanix dual wavelength UV/VIS detectors are an essential part of a high performance liquid phase purification (HPLC) system. The detector is digitized for data processing and control, reducing baseline noise and drift to a new limit. The digital output function allows the detector to be connected directly to a computer via a serial port without the need for a data acquisition unit.

The detector system uses different flow cell units for different flow rates. It is possible to detect the flow directly without diverting the flow.

Features

  • Deuterium lamp with stable signal and high energy output.
  • Flow cell selection according to different flow rates, different sizes of flow cells that can be directly detected
  • Built-in digital signal processing and control system
  • Integrated power supply, make the power supply more stable, suitable for explosion-proof use
  • Latest ARM system program control, higher accuracy
uv detector with optical fiber for HPLC sysem

UV Detector Parameter

Type

PUD0010

PUD0100 / PUD0200

PUD0500 / PUD1000

PUD3000

Flow Cell

Analysis flow cell, SST or PEEK 10mm optical range

Preparative flow cells, variable optical range in SST or PEEK

Connector

1/16

1/16 / 1/8

1/8

6mm

Wavelength Range & Light Source

190-400nm deuterium lamp,

400-700nm tungsten lamp

Bandwidth

8nm

Wavelength

Accuracy

±0.75nm

±1nm

Wavelength

Repeatability

0.2nm

0.3nm

Baseline Noise (Static)

1*10-5 AU

Baseline Drift (Static)

1*10-4 AU/h

1*10-4 AU/h

1*10-4 AU/h

1*10-4 AU/h

Detection Range

(0~5)AU

Min detection limit

≤4*10-9g/mL

≤4*10-8g/mL

≤4*10-7g/mL

≤4*10-5g/mL

Control Mode

RS232 or LAN

Display

5.0-inch touch screen

Size

368*260*140(LWH)

Wattage

75W

Weight

6.9kg

Optical Fiber Detector & Optical Fiber Flow Cell

Optical fiber detector: 190 – 700 nm, variable dual wavelength UV/VIS detector with fiber optic.

 

Optical Fiber Detector

Optical Fiber Flow Cells

PUD0010

190 – 700 nm optical fiber detector

10 mm path length, 1/16″, 10 µl volume stainless steel

PUD0050

190 – 700 nm optical fiber detector

3 mm path length, 1/16″, 2 µl volume

PUD0100

190 – 700 nm optical fiber detector

3 mm path length, 1/16″, 2 µl volume

PUD0200

190 – 700 nm optical fiber detector

3 mm path length, 1/16″, 2 µl volume

PUD0500

190 – 700 nm optical fiber detector

3 mm path length, 1/8″, 1.9 µl volume

PUD1000

190 – 700 nm optical fiber detector

3 mm path length, 1/8″, 1.9 µl volume

PUD3000

190 – 700 nm optical fiber detector

2 mm path length, 1/16″, 6.28 µl volume

Products

uv detector for HPLC sysem

UV Detector

uv detector with optical fiber for HPLC sysem

UV Detector with Optical Fiber

Don’t find the product you need? Contact us directly.

Scroll to Top
biovanix-logo

Get A Quick Quotation