Jacket-type Double-layer Glass Column
BioVanix BSXK compression glass chromatography column is made of borosilicate glass. They allow visual inspection of media beds and exhibit excellent chemical resistance. Column packing can be performed using either a packing reservoir or an extra column tube attached with a packing connector. QuickLock of the adapter shaft facilitates rapid and easy movement of the adapter, simplifying adjustments of the bed height and cleaning. The adapter plunger gives a uniform flow which maintains the integrity of the packed bed during operation.
Advantages
- Pressure-resistant glass column tube can be used to observe the column bed
- The column head ensures uniform buffer distribution and repeated loading
- Unique support foot design can adjust the level after placement
- Various specifications, inner diameter: 10, 16, 26, 50mm
- Maximum compression at one end is 17cm, and 2 * 17cm at both ends
- Direct connection with mainstream purification system
 
 Biovanix Shop
 
 Double-layer One-side Chromatography Column
 
 Double-layer Double-side Chromatography Column
 
 Adaptor
Parameter For Chromatography Column
| Working Temperature | 4-40℃ | 
| pH Range | 1-14 | 
| Chemical Stability | Tolerant to salt, acid, alkali, and a small number of organic solvents alcohols, ketones, and phenols. | 
| Column Material | Borosilicate glass | 
| Column Head Material | PTFE | 
| Thread–end Material | PEEK | 
| Seal Ring Material | PTFE/EPDM | 
| Tubing Material | 1/16 & 1/8 (optional) | 
| Connector Material | PEEK 1/16 & 1/8 (optional) | 
| Max. Pressure | 20 bar for 10/16mm I.D. 10 bar for 26mm I.D. 7 bar for 50mm I.D. | 
Chromatography Column Selection
| No. | Internal Diameter (mm) | Length (mm) | One-side Adjustable Type | Double-side Adjustable Type | ||
| Volume (mL) | Bed Height (cm) | Volume (mL) | Bed Height (cm) | |||
| BSXK10/150 | 10 | 150 | – | – | 0-10 | 0-13 | 
| BSXK10/200 | 10 | 200 | – | – | 0-12 | 0-16 | 
| BSXK10/400 | 10 | 400 | – | – | 16-28 | 21-36 | 
| BSXK10/1000 | 10 | 1000 | – | – | 63-75 | 81-96 | 
| BSXK16/200 | 16 | 200 | 6-34 | 3-17 | 0-32 | 0-16 | 
| BSXK16/400 | 16 | 400 | 46-74 | 23-37 | 20-72 | 10-36 | 
| BSXK16/700 | 16 | 700 | 86-114 | 43-57 | 80-132 | 40-66 | 
| BSXK16/1000 | 16 | 1000 | 166-194 | 83-97 | 14-192 | 70-96 | 
| BSXK26/200 | 26 | 200 | 15-90 | 3-17 | 0-84 | 0-16 | 
| BSXK26/400 | 26 | 400 | 122-196 | 23-37 | 53-191 | 10-36 | 
| BSXK26/700 | 26 | 700 | 228-302 | 43-57 | 212-350 | 40-66 | 
| BSXK26/1000 | 26 | 1000 | 440-514 | 83-97 | 37-509 | 70-96 | 
| BSXK50/200 | 50 | 200 | 58-294 | 3-15 | 0-294 | 0-15 | 
| BSXK50/300 | 50 | 300 | 255-490 | 13-25 | 0-490 | 0-5 | 
| BSXK50/600 | 50 | 600 | 824-1079 | 42-55 | 569-1079 | 29-55 | 
| BSXK50/1000 | 50 | 1000 | 1628-1864 | 83-95 | 1354-1864 | 69-95 | 
Adaptor
- 130ml
- 320ml
- 420ml
- 1200ml
Product Details For Chromatography Column
 
 Thicker borosilicate glass, higher pressure resistance
 
 Integrated molding, more durable
 
 High-quality sealing rings & sieve plates, leak-proof
 
 