Fases de intercambio iónico para la selectividad en cromatografía líquida

Fases de intercambio iónico para la selectividad en cromatografía líquida

Ion-exchange phases separate solutes on the basis of differences in ionic charge. Retention in ion-exchange chromatography is determined by the pH of the eluent, the nature and ionic strength of the buffer and temperature. Column efficiencies are lower than in reversed-phase HPLC. Eluents are normally aqueous but can contain some organic components.

Base Material

Both silica-based and polymer-based ion-exchangers are available. For the former, ionic species are attached to the silica surface, whereas for the latter the ion-exchange groups are distributed throughout the matrix. Silica-based materials maintain mechanical strength and higher efficiency advantage, whereas the polymer-based materials have greater pH stability.

Aplicaciones

Ion-exchange is used for the analysis of small ions but the key application area of the technique is the separation of biomolecules such as peptides, proteins, and oligonucleotides. Weak ion-exchangers are used for the analysis of inorganic ions, a technique more specifically termed ion chromatography.

Ion-Exchange Capacity

The exchange capacity of an ion-exchanger is an important measure of its retentivity (typically measured in milliequivalents per gram material). For any column, the packing density of the phase must also be taken into account. Wide pore materials will typically have lower ion-exchange capacities.

Cation-exchange phases contain negatively charged functional groups and retain positively charged cations. Conversely, anion-exchange phases retain negatively charged analytes by their positively charged functional groups. In the schematics below, the ion strength of the counterions can be adjusted to shift the equilibrium position and thus the retention times of the analytes.

Classification

TipoStrengthNomenclatureTypical FunctionalitypH Ionisation Range
AnionDébilWAXAmineIonised at specific pH
FuerteSAXAmonio cuaternarioIonised over complete pH range
Cation

 

 

FuerteSCXSulphonic Acid
DébilWCXÁcido carboxílicoIonised at specific pH

Biovanix Ion-exchange Phases

PhaseBase MaterialClassificationTamaño de las partículasCapacidadRango de pH
PMMA SP50PolymerSCX50um≥130 mg Lysozyme2-12
PMMA Q50SAX50um≥130 mg Lysozyme2-12
PSDVB POLY S50SCX50μm≥ 60 mg/ml hlgG2-12
PSDVB POLY CM50WCX50μm≥80 mg Lysozyme6-12
PSDVB POLY Q50SAX50μm≥ 100 mg BSA2-12
PSDVB POLY D50WAX50μm≥ 100 mg BSA2-9