| ASTM Designation | Testing Method | Method Title | Recommended GC Columns |
| D1945 | GC | Standard test method for the analysis of natural gas | GC-PLOT MoleSieve, 15mx0.53mmx50μmGC-PLOT Q, 15mx0.53mmx30μm |
| D1946 | GC | Standard test method for the analysis of reformed gas | GC-PLOT MoleSieve, 15mx0.53mmx50μmGC-PLOT Q, 15mx0.53mmx30μm |
| D1983 | GLC of methyl ether | Standard practice for measuring volatile organic matter in water | GC-INOWAX, 30mx0.25mmx0.25μm |
| D2163 | GC | Standard test method for the analysis of liquified petroleum gases and propene concentration | GC-PLOT Al2O3 “KCl”, 30mx0.53mmx15μmGC-PLOT Al2O3 “S”, 50mx0.53mmx15μm |
| D2268 | Capillary GC | Standard test method for the analysis of fatty acid compositions | GC-1, 60mx0.25mmx0.5μm |
| D2306 | GC | Standard test method for C8 aromatic hydrocarbons | GC-INOWAX, 60mx0.25mmx0.25μm |
| D2426 | GC | Standard test method for the butadiene dimer and styrene in butadiene concentration | GC-1, 30mx0.53mmx5.0μm |
| D2427 | GC | Standard test method for determination of C2 through C5 hydrocarbons in gasoline | GC-1, 30mx0.53mmx5.0μmGC-PLOT Al2O3 “M”, 30mx0.53mmx15μm |
| D2504 | GC | Standard test method for noncondensable gases in C2 and for lighter hydrocarbon products | GC-PLOT MoleSieve, 30mx0.53mmx50μm |
| D2505 | GC | Standard test method for other hydrocarbons and carbon dioxide in high-purity ethylene | GC-PLOT GasPro, 60mx0.32mmx5μm |
| D2593 | GC | Standard test method for butadiene purity and hydrocarbon impurities | GC-PLOT Al2O3 “M”, 30mx0.53mmx15μm |
| D2712 | GC | Standard test method for hydrocarbon traces in concentrated propylene | GC-PLOT Al2O3“M”, 50mx0.53mmx15μm |
| D2804 | GC | Standard test method for the purity of methyl ethyl ketone | GC-INOWAX, 30mx0.53mmx1.0μm |
| Extended D2887 | GC | Standard test method for analysis of the boiling range distribution of petroleum fractions to C60 | GC-1, 10mx0.53mmx0.88μmGC-1, 5mx0.53mmx0.88μm |
| D2908 | Aqueous- injection GC | Standard test method for the purity of halogenated organic solvents |
| D3054 | GC | Standard test method for analysis of cyclohexane | GC-1, 60mx0.32mmx0.5μm |
| D3257 | GC | Standard test method for the analysis of aromatics in mineral spirits | GC-624, 30mx0.53mmx3.0μm |
| D3329 | GC | Standard test method for the purity of methyl isobutyl ketone | GC-INOWAX, 30mx0.53mmx1.0μm |
| D3432 | GC | Standard test method for the analysis of unreacted toluene diisocyanates in urethane prepolymers and coating solutions | GC-624, 30mx0.53mmx3.0μmGC-1MS, 30mx0.32mmx1.0μm |
| D3447 | GC | Standard practice for the analysis of collected organic vapours | GC-624, 30mx0.53mmx3.0μm |
| D3534 | GC | Standard test method for the analysis of PCB’s in water | GC-1MS, 30mx0.32mmx1.0μm |
| D3545 | GC | Standard test method for the analysis of alcohol content and the purity of acetate esters | GC-624, 30mx0.53mmx3.0μm |
| D3687 | The activated charcoal tube adsorption method | Standard test method for the determination of the boiling range distribution of crude petroleum | GC-INOWAX, 30mx0.53mmx1.0μm |
| D3695 | Direct aqueous injection GC | Standard test method for the analysis of volatile alcohols in water | GC-INOWAX, 30mx0.53mmx1.0μm |
| D3760 | GC | Standard test method for the analysis of isopropylbenzene (Cumene) | GC-INOWAX, 60mx0.32mmx0.25μmGC-1, 50mx0.32mmx0.52μm |
| D3797 | GC | Standard test method for the analysis of o-xylene | GC-INOWAX, 60mx0.32mmx0.50μm |
| D3798 | GC | Standard test method for the analysis of p-xylene | GC-INOWAX, 60mx0.32mmx0.50 μm |
| D3871 | Standard test method for the analysis of purgeable organic compounds in water | Standard test method for the analysis of purgeable organic coumpounds in water | GC-624, 30mx0.53mmx3.0μm |
| D3893 | GC | Standard test method for the purity of methyl amyl ketone and methyl isoamyl ketone | GC-624, 30mx0.53mmx3.0 μm |
| D3973 | GC | Standard test method for the analysis of hydrocarbons with low molecular weights in water | GC-1, 30mx0.53mmx2.65μm |
| D4415 | GC | Standard test method for the determination of dimers in acrylic acid | GC-FFAP, 30mx0.32mmx0.25μm |
| D4424 | GC | Standard test method for butylene analyses | GC-PLOT Al2O3 “S”, 50mx0.53mmx15μm |
| D4443 | Headspace GC | Standard test method for the residual vinyl chloride monomer content in PPB in vinyl chloride homo- and copolymers | GC-1, 30mx0.53mmx2.65μm |
| D4864 | GC | Standard test method for the determination of traces of methanol in propylene concentrates | GC-INOWAX, 30mx0.53mmx1.0μmGC-PLOT Q, 30mx0.53mmx30μm |
| D4947 | GC | Standard test method for the analysis of chlordane and heptachlor residues in indoor air | GC-5, 30mx0.53mmx1.5μm |
| D4961 | GC | Standard test method for the analysis of major organic impurities in phenol produced by the cumene process | GC-PLOT Q, 15mx0.53mmx30μm |
| D4983 | Direct aqueous injection GC | Standard test method for the analysis of cyclohexylanine, morpholine, and diethylaminoethanol in water and condensed steam | GC-5MS, 30mx0.32mmx1.00μm |
| D5008 | GC | Standard test method for ethyl methyl pentonal content and the purity value of 2-ethylhexanol | GC-1, 15mx0.53mmx5.0μmGC-INOWAX, 30mx0.32mmx0.25μm |
| D5060 | GC | Standard test method for determining the impurities in high-purity ethylbenzene | GC-INOWAX, 60mx0.32mmx0.5μ |
| D5075 | GC | Standard test method for the analysis of nicotine in indoor air | GC-5, 30m x0.53mmx1.5μmGC-5, 30mx0.32mmx1.0μm |
| D5135 | Capillary GC | Standard test method for the analysis of sryreme | GC-INOWAX, 60mx0.32mmx0.5μmGC-5, 30m x0.53mmx1.5μmGC-5, 30mx0.32mmx1.0μm |
| D5303 | GC | Standard test method for the analysis of carbonyl sulfide in propylene | GC-PLOT GasPro, 30mx0.32mmx5μm |
| D5307 | GC | Standard test method for the determination of 1,1-trichloroethane and methylene chloride in stabilised trichloroethylene and tetrachloroethylene | GC-1, 7.5mx0.53mmx5.0μm |
| D5310 | Capillary GC | Standard test method for the analysis of tar acid composition | GC-5MS, 30mx0.25mmx0.25μm |
| D5316 | Standard test method for the analysis of high-purity n-heptane and iso-octane | Standard test method for 1, 2-dibromoethane and 1, 2-dibromo-3-chloropropane in water | GC-1MS, 30mx0.32mmx1.0μmGC-PLOT Q, 30mx0.53mmx30μm |
| D5317 | GC with an electron capture detector | Standard test method for the determination of chlorinated organic acid compounds in water | GC-5MS, 30mx0.25mmx0.25μm GC-1701, 30mx0.25mmx0.25μm GC-35MS, 30mx0.25mmx0.25μm |
| D5320 | GC | Standard test method for the analysis of petroleum wax | GC-1, 30mx0.53mmx3.0μmGC-624, 30mx0.32mmx1.8μm |
| D5441 | GC | Standard test method for the analysis of methyl tert-butyl ether (MTBE) | GC-PLOT Q, 30mx0.53mmx30μm |
| D5442 | GC | Standard test method for the analysis of nitrogen and phosphorus-containing pesticides in water | GC-5, 15mx0.25mmx0.25μm |
| D5475 | GC with a nitro-gen phosphorus detector | GC with a nitrogen phosphorus detector | GC-5MS, 30mx0.25mmx0.25μm GC-35MS, 30mx0.25mmx0.25μm GC-1701, 30mx0.25mmx0.25μm |
| D5501 | GC | Standard test method for the determination of ethanol content in denatured fuel ethanol | GC-1, 100mx0.25mmx0.50μm |
| D5507 | Standard test method for the determination of residual acrylonitrile monomers in styrene-acrylonitrile copolymer resins and nitrile-butadiene rubbers | Standard test method for the determination of trace organic impurities in monomer grade vinyl chloride | GC-PLOT Q 15mx0.53mmx30μmGC-PLOT U 30mx0.53mmx20 μm |
| D5508 | Headspace- capillary GC | GC and oxygen-selective flame ionisation detection | GC-PLOT Q, 30mx0.53mmx30μm |
| D5580 | GC | Standard test method for the determination of benzene, toluene, ethylbenzene, p/m-xylene, C9, and heavier aromatics, and total aromatics in finished gasoline | GC-1, 30mx0.53 mmx5.0μm |
| D5599 | GC and positive ion electron impact low resolution mass spectrometry | Standard test method for the determination of oxygenates in gasoline | GC-1, 60mx0.25mmx1.0 μm |
| D5623 | GC and sulfur selective detection | Standard test method for analysis of sulfur compounds in light petroleum liquids | GC-1, 30mx0.32mmx4.0μm |
| D5739 | Standard test method for the determination of organochlorine pesticides in water | Standard practice for oil spill source identification | GC-5, 30mx0.25mmx0.25μm |
| D5769 | GC/MS | Standard test method for the determination of benzene, toluene, and total aromatics in finished gasoline | GC-1, 60mx0.25mmx1.0μm |
| D5790 | Capillary column GC/MS | Standard practice for the measurement of purgeable organic compounds in water | GC-624, 30mx0.53mmx3.0μm |
| D5812 | Capillary column GC | GC and external calibration | GC-5MS, 30mx0.25mmx0.25μmGC-35MS, 30mx0.25mmx0.25μm |
| D5917 | Standard test method for the determination of PCBs in waste materials | Standard test method for the analysis of trace impurities in monocyclic aromatic hydrocarbons | GC-1701, 30mx0.25mmx0.25μmGC-INOWAX, 60mx0.32mmx0.25μm |
| D5986 | GC/FTIR | Standard test method for the determination of oxygenates benzene, toluene, C8-C12 aromatics, and total aromatics in finished gasoline | GC-1, 60mx0.53mmx5.0μm |
| D6144 | Capillary GC | Standard test method for the analysis of trace impurities in alpha-methylstyrene | GC-1, 60mx0.25mmx1.0μm |
| D6159 | GC | Standard test method for the determination of hydrocarbon impurities in ethylene | GC-PLOT Al2O3“KCl”, 50mx0.53mmx15μmGC-PLOT Al2O3 “M”, 50mx0.53mmx15μmGC-1, 30mx0.53mmx5.0μm |
| D6160 | GC | Standard test method for the determination of PCB’s in waste materials | GC-5MS, 30mx0.32mmx0.25μm |
| D2360 | GC | Standard test method for the analysis of trace impurities in monocylic aromatic hydrocarbons | GC-INOWAX, 60mx0.32mm x0.25μm |
| E1616 | GC | Standard test method for the analysis of acetic anhydride | GC-1, 50mx0.32mmx0.52μm |
| E1863 | GC | Standard test method for the analysis of acrylonitrile | GC-INOWAX, 30mx0.32mmx1.0μmGC-PLOT Q, 30mx0.32mmx 15.0μm |
| E202 | GC | Standard test method for the analysis of ethylene glycols and propylene glycols | GC-624, 30mx0.53mmx3.0μm |
| E475 | GC | Standard test method for the assay of di-tert-butyl peroxide | GC-5, 30mx0.53mmx5.0μm |