Hardware & Components

Precision Hardware for Chromatography Excellence

Glass Chromatoography Column, Injection Loop, Oligo Synthesis Column, Gas Chromatography Column

From glass columns to flow meters — engineered for reproducibility, built for every scale. Complete hardware portfolio for lab-scale research to industrial bioprocessing.

10–350mm

Column ID Range

2 MPa

Max Operating Pressure

USP Class VI

Biocompatibility

ISO 9001

Quality Certified

Product Portfolio

Nine product categories covering every chromatography hardware need — from analytical-scale GC columns to industrial bioprocessing systems.

BioVanix single-layer glass chromatography column

Single-Layer Glass Column

Borosilicate glass columns for lab-scale separation and purification applications.

6 Models

BioVanix double-layer glass chromatography column

Double-Layer Glass Column

Jacketed design for temperature-controlled circulation with sensitive separations.

16 Models

biovanix fixed-bed glass chromatography column

Fixed-Bed Glass Column

HT Tower series for preparative and semi-preparative separation at scale.

HT Series

BioVanix low-pressure glass chromatography column

Low-Pressure Column

Sanitary-grade compressible columns for GMP-compliant biopharma production.

Sanitary Grade

Biovanix industrial low pressure chromatography column

Industrial Low-Pressure Column

Large-scale columns with control system compatibility from 50mm to 650mm diameter.

Sanitary Grade

BioVanix glass injection loop

Injection Loop

Pressurized sample loading device for large-volume, reproducible injection.

Sanitary Grade

biovanix oligo systhesis column

Oligo Synthesis Column

Designed for oligonucleotide and peptide synthesis under harsh organic conditions.

Sanitary Grade

Biovanix gas chromatography column

Gas Chromatography Column

High-performance GC columns for precise gas-phase separation and analysis.

Sanitary Grade

Isoplex MFM FLOW Gas Mass Flow Meter

Gas Mass Flow Meter

Integrated closed-loop control with high-precision thermal mass flow sensing.

Sanitary Grade

01

Glass Chromatography Columns

Precision-engineered glass columns for every scale of chromatographic separation

Single-Layer Glass Column

Designed for lab-scale separation and purification. Ideal for biopharma R&D, natural product extraction, and process development studies.

Unique head design for uniform buffer distribution across the entire column cross-section

Snap-in screen design for quick and easy replacement without special tools

O-ring seal between head and tube — simple, reliable, and leak-free operation

Easy operation and cleaning — minimal maintenance downtime between runs

No.

Internal

Diameter

(mm)

Length

(mm)

One-side Adjustable

Type

Double-side Adjustable

Type

Pressure

(bar)

Volume

(mL)

Bed Height

(cm)

Volume (mL)

Bed Height

(cm)

YS16/200

16

200

4-30

2-14.5

0-30

0-14.5

7

YS16/400

16

400

46-72

22-34.5

17-72

8.5-34.5

7

YS16/700

16

700

109-136

52-64.5

81-136

38.5-64.5

7

YS16/1000

16

1000

173-199

82-94.5

144-199

68.5-94.5

7

YS26/200

26

200

10-73

2-14.5

0-73

0-14.5

7

YS26/400

26

400

111-174

22-34.5

43-174

8.5-34.5

7

YS26/700

26

700

263-326

52-64.5

195-326

38.5-64.5

7

Tube: Borosilicate Glass

Head: PTFE

Thread: PEEK

Seal: PTFE / EPDM

Temperature: 4–40°C

pH Range: 1–14

Double-Layer Glass Column

Jacketed design enables temperature-controlled circulation for sensitive separations. Maintains precise thermal conditions during extended runs and temperature-critical applications.

Double-layer structure for precise temperature control via external circulation

ID range: 10–50mm with bed volumes from 12 mL to 1,849 mL

Same O-ring seal & snap-in screen design as single-layer for consistency

Ideal for: protein purification, enzyme isolation, and thermally sensitive compounds

No.

Internal

Diameter

(mm)

Length

(mm)

One-side Adjustable Type

Double-side AdjustableType

 

 

 

Volume (mL)

Bed Height (cm)

Volume (mL)

Bed Height (cm)

BSXK10/100

10

100

4-7.5

0-9

0-7

0-8

BSXK10/150

10

150

7.5-12

9-12

4.7-12

5-13

BSXK16/200

16

200

4-30

2-14.5

0-30

0-14.5

BSXK16/400

16

400

46-72

22-34.5

17-72

8.5-34.5

BSXK16/700

16

700

109-136

52-64.5

81-136

38.5-64.5

BSXK16/1000

16

1000

173-199

82-94.5

144-199

68.5-94.5

BSXK26/200

26

200

10-73

2-14.5

0-73

0-14.5

BSXK26/400

26

400

111-174

22-34.5

43-174

8.5-34.5

BSXK26/700

26

700

263-326

54-64.5

195-326

38.5-64.5

BSXK26/1000

26

1000

415-479

82-94.5

347-479

68.5-94.5

BSXK50/200

50

200

19-275

1-14

0-275

0-14

BSXK50/300

50

300

215-471

11-24

0-471

0-24

BSXK50/600

50

600

804-1060

41-54

549-1060

28-54

BSXK50/1000

50

1000

1589-1849

81-94

1334-845

68-94

Wetted Materials: Borosilicate Glass + PTFE + PEEK

Jacket: Double-layer borosilicate

Application: Temperature-sensitive separations

Fixed-Bed Glass Column

HT series tower columns engineered for preparative and semi-preparative separation. Flared body and screen-free nozzle design solves distribution issues at large sample volumes, enabling superior resolution with minimal bed disturbance.

High-precision glass tube — no bubbles or scratches, prevents microbial growth

Manual screw-adjusted head for simple, efficient and reproducible packing

Sanitary design compliant with GMP requirements for pharma manufacturing

All polymer materials meet USP <88> Class VI biocompatibility requirements

No.

Inner diameter (mm)

Length

(mm)

Max.Pressure

(bar)

Silica Resin (40-60um)(g)

Sampling

 (g)

Flow Rate (mL/min)

HT10/110

10

110

40

Protective column, on-column injector.

HT-15/310

15

310

40

45

0.45-4.5

5-20

HT-15/460

15

460

40

70

0.7-7.00

5-20

HT-15/920

15

920

40

140

1.4-14.00

5-20

HT26/100

26

100

40

Protective column, on-column injector.

HT-26/310

26

310

40

130

1.30-13.00

20-70

HT-26/460

26

460

40

200

2.00-20.00

20-70

HT-26/920

26

920

40

400

4.00-40.00

20-70

HT-36/310

36

310

30

240

2.40-24.00

45-135

HT-36/460

36

460

30

350

3.50-35.00

45-135

HT-36/920

36

920

30

700

7.00-70.00

45-135

HT-49/100

49

100

20

Protective column, on-column injector.

HT-49/310

49

310

20

450

4.50-45.00

80-200

HT-49/460

49

460

20

650

6.50-65.00

80-200

HT-49/920

49

920

20

1300

13.00-130.00

80-200

HT-70/310

70

310

10

880

8.80-88.00

170-250

HT-70/460

70

460

10

1300

13.00-130.00

170-250

HT-70/920

70

920

10

2600

26.00-260.00

170-250

HT-100/310

100

310

10

1900

19.00-190.00

200-250

HT-100/460

100

460

10

2750

27.50-275.00

170-250

HT-100/920

100

920

10

5500

55.00-550.00

200-250

HT-150/300

150

300

5

3180

36.50-365.00

500-800

HT-150/600

150

600

5

6360

55.00-550.00

500-800

HT-150/900

150

900

5

9540

110.00-1100.00

500-800

Process Development

Biopharma Production

GMP Compliance

02

Low-Pressure Columns

From preparative tower columns to industrial-scale production systems

Low-Pressure Column

Sanitary-grade compressible glass column for GMP-compliant process development and biopharma production. Designed to meet the most stringent regulatory and quality requirements.

Ultra-large injection capacity: optimized for high-volume sample loading without breakthrough

Screen-free nozzle design: prevents bed damage and ensures uniform flow distribution

Pump-compatible feeding: avoids valve clogging with direct column inlet design

Pressure rating up to 40 bar for demanding preparative separations

Product

Column Inner Diameter (mm)

Sectional Area (cm2)

Column Height (mm)

Column Bed Height (cm)

Column Bed Volume (L)

Max. Pressure (bar)

Net Wight (Kg)

Min

Max

Min

Max

MPC100/500

70

38.5

500

0

35

0

1.4

8

14

MPC100/750

70

38.5

950

40

80

1.5

3.1

8

14

MPC100/500

100

78.5

500

0

35

0

2.7

8

18

MPC100/750

100

78.5

750

20

60

1.6

4.7

8

20

MPC100/950

100

78.5

950

40

80

3.1

6.3

8

21

MPC140/500

140

154

500

0

35

0

5.4

6

30

MPC140/750

140

154

750

20

60

3.1

9.2

6

33

MPC140/950

140

154

950

40

80

6.2

12.3

6

35

MPC200/500

200

314

500

0

35

0

11

6

36

MPC200/750

200

314

750

20

60

6.3

18.8

6

39

MPC200/950

200

314

950

40

80

12.6

25.1

6

42

MPC300/500

300

706.5

500

0

35

0

24.7

4

58

MPC300/750

300

706.5

750

20

60

14.1

42.4

4

63

MPC300/950

300

706.5

95

40

80

28.2

56.5

4

67

MPC450/500

450

1560

50

0

35

0

55.6

3

230

Large-Volume Sample Loading

Preparative Separation

Natural Product Extraction

Industrial Low-Pressure Column

Large-scale columns with control system compatibility from 50mm to 650mm diameter.

High-precision glass tube — no bubbles or scratches, prevents microbial growth

Sanitary design compliant with GMP requirements for pharma manufacturing

Product

Column I.D. (mm)

Column Height (mm)

Packing Height (cm)

Working Pressure (≤bar)

Net Weight (kg)

APC 300/600

300

600

5-47

4

430

APC 300/950

300

950

5-82

4

450

APC 400/600

400

600

5-47

4

480

APC 400/950

400

950

5-82

4

510

APC 450/600

450

600

5-47

4

750

APC 450/950

450

950

5-82

4

800

APC 600/600

600

600

5-47

4

900

APC 600/950

600

950

5-82

4

970

APC 800/600

800

600

5-47

4

2100

APC 800/950

800

950

5-82

4

2200

APC 1000/600

1000

600

5-47

4

2700

APC 1000/950

1000

950

5-82

4

2850

APC 1200/600

1200

600

5-47

4

4800

APC 1200/950

1200

950

5-82

4

5100

Process Development

Biopharma Production

GMP Compliance

03

Injection Loop

Pressurized sample loading for precise, reproducible sample introduction

Pressurized sample loading device for large-volume injection. Works seamlessly with sample valves for precise, reproducible sample introduction. Dynamic internal sealing ensures samples are injected without dilution.

lexible injection volumes: 10 mL, 50 mL, and 150 mL options for diverse applications

Dynamic internal sealing: sample injected without dilution for maximum sensitivity

High reproducibility and recovery: consistent sample introduction run after run

Pressure-rated: up to 4 MPa for high-pressure HPLC system compatibility

ModelVolumeMax Pressure
Injection Loop-1010 mL2 MPa
Injection Loop-5050 mL4 MPa
Injection Loop-150150 mL2 MPa

Pairs Perfectly With

v7725i Sample Valve

Isoplex HPLC Systems

Glass Chromatography Columns

04

Oligo Synthesis Column

Purpose-built for oligonucleotide and peptide synthesis under demanding conditions

Designed for oligonucleotide and peptide synthesis applications. Engineered to withstand harsh organic solvents and reactive conditions with full chemical resistance and reliable performance.

Small Oligo Columns

Small stainless steel synthesis columns are engineered as fixed-volume synthesis column reactors—complete with filters and seals—for oligonucleotide synthesis.  

Advantage  

  • These syntheticcolumns are produced to stringent standards, ensuring durability under the harsh organic conditions encountered during oligonucleotide synthesis.  
  • 316L stainless steel.

Product

Volume

Inner Diameter

Height

Oligo1.2

1.2ml

10mm

15mm

Oligo6.3

6.3ml

20mm

20mm

Oligo12

12ml

27mm

21mm

Oligo24

24ml

35mm

25mm

Oligo48

48ml

44mm

32mm

Oligo Synthesis Column

Designed for the synthesis of oligonucleotides, Biovanix oligo synthesis columns are engineered to endure the demanding organic conditions typical in the synthesis process.

Advantage

  • Adjustable column bed height, ideally set between 3 to 10 cm for optimal performance.
  • A 35mm column diameter with a capacity ranging from 10mL to 100mL.
  • Built to endure the stringent organic conditions prevalent in oligonucleotide synthesis.
  • User-friendly operation with an efficient solid-phase carrier packing process.

Product

Inner Diameter

Packing Length

Pressure Resistance

Weight (kg)

Oligo35 Column

35mm

0-150mm

2Mpa

2

Oligo50 Column

50mm

30-150mm

2Mpa

4

Oligo70 Column

70mm

30-150mm

2Mpa

10

Oligo100 Column

100mm

30-150mm

2Mpa

17

Oligo200 Column

200mm

30-150mm

2Mpa

68

Oligo350 Column

350mm

30-150mm

2Mpa

250

Oligo70L Column

70mm

50-300mm

2Mpa

13

Oligo100L Column

100mm

50-300mm

2Mpa

21

Oligo200L Column

200mm

50-300mm

2Mpa

83

Oligo350L Column

350mm

50-300mm

2Mpa

270

Oligo140 Column

140mm

30-150mm

2Mpa

31

Oligo140L Column

140mm

50-300mm

2Mpa

36

Customization options available, including sizes with diameters of 70mm, 100mm, 200mm, and 350mm.

05

Gas Chromatography Column

High-performance GC columns

High-performance GC columns for precise gas-phase separation and analysis. Available in capillary and packed column configurations for a wide range of analytical applications.

Column types: Capillary columns and packed columns for diverse analytical needs

Long service life: durable stationary phase for extended column lifetime

High resolution with excellent thermal stability for reproducible separations

Applications: Environmental monitoring, petrochemical, food safety, quality control

Environmental Analysis

Petrochemical

Food Safety

Quality Control

06

Gas Mass Flow Meter

Integrated closed-loop control combining a high-precision mass flow sensor, laminar flow element, solenoid valve, and precision amplifier circuit. Delivers accurate gas flow measurement and control for critical processes.

Working Principle

Thermal mass flow principle — measures gas molecular quantity directly. No temperature or pressure compensation needed. Provides true mass flow measurement regardless of operating conditions.

Three Range Series Comparison

SpecificationSmall RangeMedium RangeLarge Range
Flow Range5–500 mln/min30–300 slm300–3,000 slm
Accuracy±1.0% F.S±1.0% S.P±1.0% F.S
Range Ratio50:150:150:1
Response Time1–4 sec1–4 sec1–4 sec
Max Pressure3 MPa30 bar3 MPa
Contact MaterialSS316SS316SS316

Technology Highlights

Thermal Sensing

Direct molecular measurement, no environmental compensation required

Laminar Flow Element

Stable flow field with excellent linearity across the entire measurement range

Micro-Flow Excellence

Short warm-up time with minimal zero drift for reliable measurements

Anti-Interference

Multi-layer PCB design with superior EMC performance

Semiconductor

Laboratory Analysis

Fuel Cell R&D

Environmental Monitoring

Precision Coating

Gas Color Coding Standards

Red — Toxic / Hazardous gases
Yellow — Flammable gases
Gray — Inert gases

Selection parameters: Power supply, fittings type, seal materials, and signal output options available upon request.

Application Scenarios

Recommended product combinations for common chromatography workflows. Find the right hardware configuration for your application.

Biopharma Process Development

Natural Product Extraction

Oligonucleotide Synthesis

Preparative Purification

Gas Analysis & Monitoring

Industrial Scale Production

Why Buy Hardware Separately?

Save time and ensure compatibility with our pre-configured hardware and consumable bundles. Every combination is tested and validated for optimal performance.

Column + Resin Bundle

Glass Column pre-packed with your choice of chromatography resin. Factory-validated for consistent performance and ready to run out of the box.

Hardware + System Package

Complete column and Isoplex HPLC system package. Pre-configured with matched fittings, tubing, and method templates for immediate use.

Full Lab Setup

Complete chromatography lab solution: Glass Column + Pump + Detector + TFF system. Custom-configured to your workflow and scale requirements.

Ready to Scale Up Your Chromatography?

Our engineering team provides custom column configuration, resin packing services, and technical support. Get a quote within 24 hours.

Scroll to Top
biovanix-logo

Get A Quick Quotation