Hardware & Components

Precision Hardware for Chromatography Excellence

Glass Chromatoography Column, Injection Loop, Oligo Synthesis Column, Gas Chromatography Column

From glass columns to flow meters — engineered for reproducibility, built for every scale. Complete hardware portfolio for lab-scale research to industrial bioprocessing.

10–350mm

Column ID Range

2 MPa

Pression de fonctionnement maximale

USP Class VI

Biocompatibility

ISO 9001

Quality Certified

Product Portfolio

Nine product categories covering every chromatography hardware need — from analytical-scale GC columns to industrial bioprocessing systems.

Colonne de chromatographie en verre monocouche BioVanix

Single-Layer Glass Column

Borosilicate glass columns for lab-scale separation and purification applications.

6 Models

Colonne de chromatographie en verre double couche BioVanix

Double-Layer Glass Column

Jacketed design for temperature-controlled circulation with sensitive separations.

16 Models

colonne de chromatographie en verre à lit fixe biovanix

Fixed-Bed Glass Column

HT Tower series for preparative and semi-preparative separation at scale.

HT Series

Colonne de chromatographie en verre à basse pression BioVanix

Low-Pressure Column

Sanitary-grade compressible columns for GMP-compliant biopharma production.

Sanitary Grade

Colonne de chromatographie industrielle Biovanix basse pression

Industrial Low-Pressure Column

Large-scale columns with control system compatibility from 50mm to 650mm diameter.e.

Sanitary Grade

Boucle d'injection en verre BioVanix

Boucle d'injection

Pressurized sample loading device for large-volume, reproducible injection.

Sanitary Grade

colonne biovanix oligo systhesis

Colonne de synthèse d'oligo

Designed for oligonucleotide and peptide synthesis under harsh organic conditions.

Sanitary Grade

Colonne de chromatographie en phase gazeuse Biovanix

Colonne de chromatographie en phase gazeuse

High-performance GC columns for precise gas-phase separation and analysis.

Sanitary Grade

Débitmètre massique de gaz Isoplex MFM FLOW

Débitmètre massique de gaz

Integrated closed-loop control with high-precision thermal mass flow sensing.

Sanitary Grade

01

Colonnes chromatographiques en verre

Precision-engineered glass columns for every scale of chromatographic separation

Single-Layer Glass Column

Designed for lab-scale separation and purification. Ideal for biopharma R&D, natural product extraction, and process development studies.

Unique head design for uniform buffer distribution across the entire column cross-section

Snap-in screen design for quick and easy replacement without special tools

O-ring seal between head and tube — simple, reliable, and leak-free operation

Easy operation and cleaning — minimal maintenance downtime between runs

No.

Interne

Diameter

(mm)

Longueur

(mm)

One-side Adjustable

Type

Double-side Adjustable

Type

Pression

(barre)

Volume

(mL)

Bed Hauteur

(cm)

Volume (mL)

Bed Hauteur

(cm)

YS16/200

16

200

4-30

2-14.5

0-30

0-14.5

7

YS16/400

16

400

46-72

22-34.5

17-72

8.5-34.5

7

YS16/700

16

700

109-136

52-64.5

81-136

38.5-64.5

7

YS16/1000

16

1000

173-199

82-94.5

144-199

68.5-94.5

7

YS26/200

26

200

10-73

2-14.5

0-73

0-14.5

7

YS26/400

26

400

111-174

22-34.5

43-174

8.5-34.5

7

YS26/700

26

700

263-326

52-64.5

195-326

38.5-64.5

7

Tube: Borosilicate Glass

Head: PTFE

Thread: PEEK

Seal: PTFE / EPDM

Température : 4–40°C

pH Range: 1–14

Double-Layer Glass Column

Jacketed design enables temperature-controlled circulation for sensitive separations. Maintains precise thermal conditions during extended runs and temperature-critical applications.

Double-layer structure for precise temperature control via external circulation

ID range: 10–50mm with bed volumes from 12 mL to 1,849 mL

Same O-ring seal & snap-in screen design as single-layer for consistency

Ideal for: protein purification, enzyme isolation, and thermally sensitive compounds

No.

Interne

Diameter

(mm)

Longueur

(mm)

Type réglable d'un côté

Double-side AdjustableType

 

 

 

Volume (mL)

Bed Hauteur (cm)

Volume (mL)

Bed Hauteur (cm)

BSXK10/100

10

100

4-7.5

0-9

0-7

0-8

BSXK10/150

10

150

7.5-12

9-12

4.7-12

5-13

BSXK16/200

16

200

4-30

2-14.5

0-30

0-14.5

BSXK16/400

16

400

46-72

22-34.5

17-72

8.5-34.5

BSXK16/700

16

700

109-136

52-64.5

81-136

38.5-64.5

BSXK16/1000

16

1000

173-199

82-94.5

144-199

68.5-94.5

BSXK26/200

26

200

10-73

2-14.5

0-73

0-14.5

BSXK26/400

26

400

111-174

22-34.5

43-174

8.5-34.5

BSXK26/700

26

700

263-326

54-64.5

195-326

38.5-64.5

BSXK26/1000

26

1000

415-479

82-94.5

347-479

68.5-94.5

BSXK50/200

50

200

19-275

1-14

0-275

0-14

BSXK50/300

50

300

215-471

11-24

0-471

0-24

BSXK50/600

50

600

804-1060

41-54

549-1060

28-54

BSXK50/1000

50

1000

1589-1849

81-94

1334-845

68-94

Wetted Materials: Borosilicate Glass + PTFE + PEEK

Jacket: Double-layer borosilicate

Application: Temperature-sensitive separations

Fixed-Bed Glass Column

HT series tower columns engineered for preparative and semi-preparative separation. Flared body and screen-free nozzle design solves distribution issues at large sample volumes, enabling superior resolution with minimal bed disturbance.

High-precision glass tube — no bubbles or scratches, prevents microbial growth

Manual screw-adjusted head for simple, efficient and reproducible packing

Sanitary design compliant with GMP requirements for pharma manufacturing

All polymer materials meet USP <88> Class VI biocompatibility requirements

No.

Inner diameter (mm)

Longueur

(mm)

Max.Pression

(bar)

Silice Resin (40-60um)(g)

Sampling

 (g)

Flow Rate (mL/min)

HT10/110

10

110

40

Protective column, on-column injector.

HT-15/310

15

310

40

45

0.45-4.5

5-20

HT-15/460

15

460

40

70

0.7-7.00

5-20

HT-15/920

15

920

40

140

1.4-14.00

5-20

HT26/100

26

100

40

Protective column, on-column injector.

HT-26/310

26

310

40

130

1.30-13.00

20-70

HT-26/460

26

460

40

200

2.00-20.00

20-70

HT-26/920

26

920

40

400

4.00-40.00

20-70

HT-36/310

36

310

30

240

2.40-24.00

45-135

HT-36/460

36

460

30

350

3.50-35.00

45-135

HT-36/920

36

920

30

700

7.00-70.00

45-135

HT-49/100

49

100

20

Protective column, on-column injector.

HT-49/310

49

310

20

450

4.50-45.00

80-200

HT-49/460

49

460

20

650

6.50-65.00

80-200

HT-49/920

49

920

20

1300

13.00-130.00

80-200

HT-70/310

70

310

10

880

8.80-88.00

170-250

HT-70/460

70

460

10

1300

13.00-130.00

170-250

HT-70/920

70

920

10

2600

26.00-260.00

170-250

HT-100/310

100

310

10

1900

19.00-190.00

200-250

HT-100/460

100

460

10

2750

27.50-275.00

170-250

HT-100/920

100

920

10

5500

55.00-550.00

200-250

HT-150/300

150

300

5

3180

36.50-365.00

500-800

HT-150/600

150

600

5

6360

55.00-550.00

500-800

HT-150/900

150

900

5

9540

110.00-1100.00

500-800

Process Development

Biopharma Production

GMP Compliance

02

Low-Pressure Columns

From preparative tower columns to industrial-scale production systems

Low-Pressure Column

Sanitary-grade compressible glass column for GMP-compliant process development and biopharma production. Designed to meet the most stringent regulatory and quality requirements.

Ultra-large injection capacity: optimized for high-volume sample loading without breakthrough

Screen-free nozzle design: prevents bed damage and ensures uniform flow distribution

Pump-compatible feeding: avoids valve clogging with direct column inlet design

Pressure rating up to 40 bar for demanding preparative separations

Produit

Colonne Inner Diameter (mm)

Sectional Zone (cm2)

Colonne Hauteur (mm)

Lit de colonne Hauteur (cm)

Colonne Bed Volume (L)

Max. Pression (bar)

Net Wight (Kg)

Min

Max

Min

Max

MPC100/500

70

38.5

500

0

35

0

1.4

8

14

MPC100/750

70

38.5

950

40

80

1.5

3.1

8

14

MPC100/500

100

78.5

500

0

35

0

2.7

8

18

MPC100/750

100

78.5

750

20

60

1.6

4.7

8

20

MPC100/950

100

78.5

950

40

80

3.1

6.3

8

21

MPC140/500

140

154

500

0

35

0

5.4

6

30

MPC140/750

140

154

750

20

60

3.1

9.2

6

33

MPC140/950

140

154

950

40

80

6.2

12.3

6

35

MPC200/500

200

314

500

0

35

0

11

6

36

MPC200/750

200

314

750

20

60

6.3

18.8

6

39

MPC200/950

200

314

950

40

80

12.6

25.1

6

42

MPC300/500

300

706.5

500

0

35

0

24.7

4

58

MPC300/750

300

706.5

750

20

60

14.1

42.4

4

63

MPC300/950

300

706.5

95

40

80

28.2

56.5

4

67

MPC450/500

450

1560

50

0

35

0

55.6

3

230

Large-Volume Sample Loading

Preparative Separation

Natural Product Extraction

Industrial Low-Pressure Column

Scale-up solutions for industrial biopharma production. Compatible with control systems from 50mm to 650mm diameter, enabling seamless technology transfer from lab to manufacturing.

High-precision glass tube — no bubbles or scratches, prevents microbial growth

Manual screw-adjusted head for simple, efficient and reproducible packing

Sanitary design compliant with GMP requirements for pharma manufacturing

All polymer materials meet USP <88> Class VI biocompatibility requirements

Produit

ID de la colonne (mm)

Hauteur de la colonne (mm)

Hauteur d'emballage (cm)

Pression de service (≤bar)

Poids net (kg)

APC 300/600

300

600

5-47

4

430

APC 300/950

300

950

5-82

4

450

APC 400/600

400

600

5-47

4

480

APC 400/950

400

950

5-82

4

510

APC 450/600

450

600

5-47

4

750

APC 450/950

450

950

5-82

4

800

APC 600/600

600

600

5-47

4

900

APC 600/950

600

950

5-82

4

970

APC 800/600

800

600

5-47

4

2100

APC 800/950

800

950

5-82

4

2200

APC 1000/600

1000

600

5-47

4

2700

APC 1000/950

1000

950

5-82

4

2850

APC 1200/600

1200

600

5-47

4

4800

APC 1200/950

1200

950

5-82

4

5100

Process Development

Biopharma Production

GMP Compliance

Défiler vers le haut
biovanix-logo

Obtenir un devis rapide