Elevate Your HPLC Performance with the Biovanix Dual Wavelength UV/VIS Detector

Achieve Unprecedented Precision and Stability in Liquid Phase Purification

For high-performance liquid chromatography (HPLC) purification systems, the quality of your detector is paramount to the integrity and reliability of your results. The Biovanix Dual Wavelength UV/VIS Detector is engineered to meet the stringent demands of modern separation science, offering a fully digitized platform that sets a new standard for baseline stability and data accuracy.

UV Detector Parameter

Type

PUD0010

PUD0100 / PUD0200

PUD0500 / PUD1000

PUD3000

Flow Cell

Analysis flow cell, SST or PEEK 10mm optical range

Preparative flow cells, variable optical range in SST or PEEK

Connector

1/16

1/16 / 1/8

1/8

6mm

Wavelength Range & Light Source

190-400nm deuterium lamp,

400-700nm tungsten lamp

Bandwidth

8nm

Wavelength

Accuracy

±0.75nm

±1nm

Wavelength

Repeatability

0.2nm

0.3nm

Baseline Noise (Static)

1*10-5 AU

Baseline Drift (Static)

1*10-4 AU/h

1*10-4 AU/h

1*10-4 AU/h

1*10-4 AU/h

Detection Range

(0~5)AU

Min detection limit

≤4*10-9g/mL

≤4*10-8g/mL

≤4*10-7g/mL

≤4*10-5g/mL

Control Mode

RS232 or LAN

Display

5.0-inch touch screen

Size

368*260*140(LWH)

Wattage

75W

Poids

6.9kg

Optical Fiber Detector & Optical Fiber Flow Cell

Optical fiber detector: 190 – 700 nm, variable dual wavelength UV/VIS detector with fiber optic.

 

Optical Fiber Detector

Optical Fiber Flow Cells

PUD0010

190 – 700 nm optical fiber detector

10 mm path length, 1/16″, 10 µl volume stainless steel

PUD0050

190 – 700 nm optical fiber detector

3 mm path length, 1/16″, 2 µl volume

PUD0100

190 – 700 nm optical fiber detector

3 mm path length, 1/16″, 2 µl volume

PUD0200

190 – 700 nm optical fiber detector

3 mm path length, 1/16″, 2 µl volume

PUD0500

190 – 700 nm optical fiber detector

3 mm path length, 1/8″, 1.9 µl volume

PUD1000

190 – 700 nm optical fiber detector

3 mm path length, 1/8″, 1.9 µl volume

PUD3000

190 – 700 nm optical fiber detector

2 mm path length, 1/16″, 6.28 µl volume

Key Value Proposition: Digitize Your Data, Eliminate the Noise

Traditional detectors introduce noise and drift through analog data acquisition. The Biovanix detector fundamentally transforms this by integrating a built-in digital signal processing and control system.

  • Noise Reduction: Data is digitized directly at the source, reducing baseline noise and drift to a new limit.

  • Simplified Integration: The digital output function allows for direct connection to a computer via a serial port, completely eliminating the need for an external data acquisition unit (DAU). This saves bench space, reduces complexity, and ensures signal fidelity.

Core Features Designed for Reliability and Accuracy

Biovanix advanced design ensures optimal performance across all your purification protocols.

FeatureTechnical BenefitUser Advantage
Integrated Digital ControlBuilt-in DSP and control systemReduced Setup Time and pristine data quality.
High-Performance LampDeuterium lamp with stable signal and high energy outputConsistent and sensitive detection across various wavelengths.
Flow Cell FlexibilityFlow cell units selectable for different flow rates and sizesDirect Flow Detection without diverting the sample, preserving resolution and minimizing hold-up volume.
Advanced System ControlLatest ARM system program controlHigher accuracy and reproducible separation results.
Integrated Power SupplyStable and self-contained power managementEnhanced Stability and suitable for use in explosion-proof environments.

Seamless Integration and Operational Excellence

The Biovanix detector is designed for operators who demand both high performance and ease of use.

Direct Detection, Maximum Efficiency

The system supports different flow cell units tailored to specific flow rates. This crucial design allows you to detect the flow directly without the need for flow splitting or diverting the stream. This direct path maintains the highest possible concentration, ensuring maximum sensitivity and quantitative accuracy.

Stability You Can Trust

The detector features an integrated power supply, which ensures power stability far superior to external units. This is critical for maintaining baseline performance, especially in long-run purification protocols or challenging industrial settings, making it suitable for explosion-proof applications.

Produits

uv detector for HPLC sysem

UV Detector

uv detector with optical fiber for HPLC sysem

UV Detector with Optical Fiber

Optimize Your Results: Applications

Biovanix Dual Wavelength UV/VIS Detector is the ideal choice for demanding applications in:

  • Pharmaceutical Development: Quality control and purification of Active Pharmaceutical Ingredients (APIs).
  • Biotechnology: Separation and monitoring of proteins, peptides, and nucleic acids.
  • Chemical Synthesis: Monitoring reaction progress and purification of complex organic molecules.

Ready to Digitize Your HPLC Workflow?

Stop compromising your data with outdated analog systems. Upgrade to the Biovanix Dual Wavelength UV/VIS Detector and experience the difference that true digital control makes.

✨ Click below to request a detailed specification sheet and a personalized quote.

Vous ne trouvez pas le produit dont vous avez besoin ? Contactez nous directement.

Défiler vers le haut
biovanix-logo