Fixed-bed Glass Chromatography Column

Biovanix HT series chromatographic columns have a unique flared cylinder design for more even fluid distribution. The column uses the unique nozzle instead of the sieve plate, which is especially suitable for solid sample loading and dry sample mixing. It effectively prevents the destruction of the column bed caused by the high mobile phase line velocity. HT chromatographic column has a large volume of sample loading. It can be pumped to eliminate the blocking of the inlet valve interface caused by a high concentration of samples.

HT series chromatography column is suitable for reverse phase, ion exchange, gel permeation, and affinity chromatography. Compared with ordinary open glass columns, the purification time is shortened 2-10 times with higher purification efficiency and less solvent usage. The column tube is convenient to disassemble and wash, saving the researchers precious time.

Biovanix Fixed-bed Glass Chromatography Column

Column Selection

Нет.Inner diameter (mm)Длина (mm)

Max.

Pressure

 (bar)

Silica Resin (40-60um) (g)Sampling (g)Flow Rate (mL/min)
HT10/1101011040Protective column, on-column injector.
HT-15/3101531040450.45-4.55-20
HT-15/4601546040700.7-7.005-20
HT-15/92015920401401.4-14.005-20
HT26/1002610040Protective column, on-column injector.
HT-26/31026310401301.30-13.0020-70
HT-26/46026460402002.00-20.0020-70
HT-26/92026920404004.00-40.0020-70
HT-36/31036310302402.40-24.0045-135
HT-36/46036460303503.50-35.0045-135
HT-36/92036920307007.00-70.0045-135
HT-49/1004910020Protective column, on-column injector.
HT-49/31049310204504.50-45.0080-200
HT-49/46049460206506.50-65.0080-200
HT-49/9204992020130013.00-130.0080-200
HT-70/31070310108808.80-88.00170-250
HT-70/4607046010130013.00-130.00170-250
HT-70/9207092010260026.00-260.00170-250
HT-100/31010031010190019.00-190.00200-250
HT-100/46010046010275027.50-275.00170-250
HT-100/92010092010550055.00-550.00200-250
HT-150/3001503005318036.50-365.00500-800
HT-150/6001506005636055.00-550.00500-800
HT-150/90015090059540110.00-1100.00500-800

Продукт

Стеклянная хроматографическая колонка с фиксированным слоем biovanix

Fixed-bed Column

Product Details

Biovanix Fixed-bed Glass Chromatography Column
Biovanix Fixed-bed Glass Chromatography Column
Biovanix Fixed-bed Glass Chromatography Column
Biovanix fix-bed glass chromatography column

How to test the fixed-bed chromatography column?

Не нашли нужный вам продукт? Свяжитесь с нами напрямую.

Прокрутить к верху
biovanix-logo

Получите быстрое предложение

Пожалуйста, включите JavaScript в вашем браузере, чтобы заполнить эту форму.