ISO Certified Manufacturer
Precision Prepacked HPLC Columns for Unmatched Separation Performance
High-Performance Liquid Chromatography (HPLC) columns are essential tools in modern analytical chemistry, widely used in pharmaceutical development, biomedical research, food safety testing, and environmental monitoring. HPLC columns achieve the efficient separation of complex mixtures by exploiting the differences in the distribution of solutes between the stationary phase and the mobile phase.
10,000
2.1–50
pH 2–12
20+
Technical Advantages
Engineered for Reproducibility, High Pressure Resistance & Superior Peak Resolution
Every Biovanix HPLC column is designed to deliver consistent, high-quality separations across a wide range of analytical conditions.
Stationary Phase Types
Common stationary phases include silica, polymers, and chemically modified materials such as C18, C8, NH₂, etc. Different stationary phases are suitable for the separation of compounds with varying polarities.
Размер частиц и размер пор
Particle sizes typically range from 1.8 µm to 10 µm, while pore sizes vary depending on the application, such as 100 Å, 200 Å, and 300 Å. Smaller particles can enhance separation efficiency but may require higher operating pressures.
Column Length and Inner Diameter
The selection of column length and inner diameter depends on the separation requirements. Longer columns generally provide higher separation efficiency.
Стабильность pH
Some HPLC columns can operate stably over a broad pH range (e.g., pH 2-12), enabling flexible method development with aggressive mobile phases.
Товарный каталог
Comprehensive HPLC Column Portfolio
Explore our full range of prepacked chromatography columns organized by application category. Click any product to learn more.
Приложения
Trusted Across Industries
From drug development to environmental protection, Biovanix HPLC columns deliver reliable performance where it matters most.
Pharmaceutical Development
Used for the separation, purification, and quality control of drug components to ensure the safety and efficacy of pharmaceuticals.
Biomedical Research
Analyzes biomolecules (such as proteins and peptides) and metabolites to support life science research.
Food Safety Testing
Detects harmful substances like additives and pesticide residues in food.
Мониторинг окружающей среды
Monitors organic pollutants and pesticide residues in water and soil.
Selection Guide
How to Choose the Right HPLC Column
Selecting the optimal column dimension and stationary phase is critical for achieving the best separation results.
HIC Column | |||||
HbA1C Column | |||||
|
|
| |||
| Амидная колонка |
|
|
| Ghost Peak Column |
В зависимости от масштаба и/или эффективности требуемого разделения, приведенная ниже таблица поможет вам выбрать колонку с наиболее подходящим внутренним диаметром (I.D.) и длиной колонки для ваших нужд.
Какая длина колонны лучше всего подходит для моих нужд?
- Если вы хотите максимально увеличить скорость работы → от 20 мм до 75 мм
- Если вам нужен баланс между разрешением и скоростью → 100 мм
- Если вам нужно максимальное разрешение → 150 мм
- Также доступны аналитические и полуаналитические размеры
Колонки USP (United States Pharmacopeia) - это колонки для высокоэффективной жидкостной хроматографии (ВЭЖХ), разработанные в соответствии со строгими стандартами, установленными USP, что обеспечивает последовательность, надежность и соответствие аналитических процедур. Эти колонки широко используются в фармацевтике, экологии и безопасности пищевых продуктов для получения точных и воспроизводимых результатов.
Why Biovanix
Why Choose Biovanix HPLC Columns?
Every column is engineered and manufactured to the highest standards, backed by our commitment to quality and technical support.
01
High-Pressure Stability
Withstands up to 10,000 psi for UHPLC applications
Materials: 316L stainless steel or biocompatible PEEK
02
Exceptional Peak Resolution
Mirror-polished inner surface (Ra ≤0.2 μm) minimizes band broadening, delivering sharp, well-defined peaks for precise quantification.
03
Настраиваемые параметры
Column dimensions: 2.1–50 mm ID | 20–500 mm length
Packing materials: C18, C8, HILIC, ion exchange, affinity resins
04
Wide pH Range
Compatible with aggressive mobile phases across a broad pH range, enabling flexible method development for diverse analytes.
05
Low Dead Volume Design
Ensures minimal sample loss and high reproducibility, critical for trace-level analysis and quantitative accuracy.
Need Custom Specifications?
Our engineering team can tailor column dimensions, stationary phases, and end fittings to your exact requirements.
FAQ
Frequently Asked Questions
Everything you need to know about Biovanix prepacked HPLC columns.
What are prepacked HPLC columns and how do they work?
What types of HPLC columns does Biovanix offer?
- Reversed-Phase Columns — C18, C18H, C18L, C18AQ, C18BS, C8, C4-300, Phenyl
- Normal-Phase Columns — SiO₂, NH₂, CN, Diol, Amide
- Small-Molecule Columns — HILIC, Ion Exchange (SCX/SAX), Sugar Analysis
- Biological Columns — SEC (SEC-120/150/300/500/1000), HIC, DNA
- Specialty Columns — Chiral (8 types), Protein A, HbA1c
- Consumables — SS/PEEK column tubing, guard columns, inline filters, frits, fittings
What is the maximum operating pressure for Biovanix HPLC columns?
| Размер частиц | Макс. Давление |
|---|---|
| 10 μm | 4,000 psi |
| 5 μm | 5,000 psi |
| 3 мкм | 6,000 psi |
| SEC (3 μm) | 2,500 psi |
| SEC (5 μm) | 1,500 psi |
| UHPLC applications | Up to 10,000 psi |
Temperature limits: 60 °C for reversed-phase columns; 40 °C for SEC columns.
Can I customize HPLC column dimensions and packing materials?
- Inner diameter: 2.1–50 mm (10 standard sizes); non-standard sizes available upon request.
- Column length: 20–500 mm (8 standard lengths); custom lengths accepted.
- Упаковочные материалы: C18, C8, Phenyl, NH₂, CN, Diol, Bare Silica and more (particle sizes 3–50 μm; pore sizes 100/120/300 Å). Special bonded phases are available upon request.
- Аппаратное обеспечение: 316L stainless steel or PEEK tubing; multiple frit types; custom end fittings and seals.
Are Biovanix HPLC columns suitable for pharmaceutical quality control?
- Columns carry recognized USP codes (L1, L3, L7, L8, L9, L10, L11, L14), enabling direct compliance with pharmacopeial methods.
- Ultra-pure silica with metal ions < 20 ppm ensures minimal peak tailing for basic compounds.
- Proprietary bonding chemistry with deep endcapping delivers low silanol activity and excellent batch-to-batch reproducibility.
- pH stability from 2–8 (up to 1–12 for C18BS) covers diverse mobile phase conditions.
- Manufacturing follows ISO 9001 quality standards.
- Applications explicitly include drug substance characterization, impurity profiling, dissolution testing, and content uniformity analysis.
How do I select the right HPLC column for my application?
- Hydrophobic compounds → C18 / C8 (reversed-phase)
- Aromatic compounds → Phenyl
- Polar compounds → HILIC / Amide
- Sugars → Sugar-10H / NH₂
- Proteins/antibodies → SEC-300 / C4-300
- Enantiomers → Chiral columns
- Analytical QC: 2.1–4.6 mm ID × 100–250 mm length
- Semi-preparative: 7.8–10 mm ID
- Preparative: 20–50 mm ID
- 3 μm: highest resolution (pharmacopeial methods)
- 5 μm: optimal balance (most common)
- 10 μm: low pressure, scalable to preparative
- 100 Å: small molecules (< 3 kDa)
- 300 Å: peptides and proteins
- SEC series: size-based separation of biomolecules
Ready to Optimize Your Chromatography?
Get detailed pricing, technical specifications, and custom column consultation from our experts.