Fase de Columna GC USP

Código USPFase estacionariaColumnas GCRango de temperatura(°C)Columnas GC equivalentes
G1Dimetilpolisiloxano, aceiteGC-1GC-1MSGC-1MS Inerte-60 a 325/350HP-1, DB-1, VF-1, Rtx-1, Rxi-1, SP-1, ZB-1HP-1MS, DB-1MS, CP-Sil 5CB MS, VF-1MS, Rtx-1MS, Rxi-1MS
G2Goma de dimetilsiloxanoGC-1 GC-1MSGC-1MS Inerte-60 a 325/350HP-1, DB-1, VF-1, Rtx-1, Rxi-1, SP-1, ZB-1 HP-1MS, DB-1MS, CP-Sil 5CB MS, VF-1MS, Rtx-1MS, Rxi-1MS
G350% fenil 50% metilpolisiloxanoGC-50+ MS40 a 320/340DB-17, DB-17MS, HP-50+, CP-Sil 24CB, VF-17MSRxt-50, Rtx-17
G750% cianopropilmetil-50% fenilmetilpolisiloxanoGC-225MS40 a 220/240DB-225, DB-225MS, Rtx-225
G14Polietilenglicol peso molecular promedio 950-1,050GC-INOWAX40 a 260/280HP-Innowax, DB-Wax, DB-Waxer, CP-Wax 52, VF-WaxRxt-Stabilwax, Rtx-Wax, Omega-Wax
G15Polietilenglicol peso molecular promedio 3,000-3,700GC-INOWAXGC-CarboWax20M GC-Wax-AQGC-INOWAX40 a 260/280HP-Innowax, DB-Wax, DB-Waxer, CP-Wax 52, VF-WaxRxt-Stabilwax, Rtx-Wax, Omega-Wax, HP-20M, DB-CAMCP-Sil 57Wax
G16Polietilenglicol peso molecular promedio 15,000GC-CarboWax20MGC-Wax-AQ40 a 200/220HP-20M, DB-CAM, CP-Sil 57Wax
G17Poli(75% difenil-25% dimetilsiloxano)GC-50+ MS40 a 320/340DB-17, DB-17MS, HP-50+, CP-Sil 24CB, VF-17MSRxt-50, Rtx-17
G20Polietilenglicol peso molecular promedio 380-420 PolietilenglicolGC-INOWAX40 a 260/280HP-Innowax, DB-Wax, DB-Waxer, CP-Wax 52, VF-WaxRxt-Stabilwax, Rtx-Wax, Omega-Wax
G25Ácido tereftálico TPA (Carbowax 20M)GC-FFAP40 a 260/280HP-FFAP, DB-FFAP, Rxt-Stabilwa-DA, CP-FFAP
G275% fenil 95% metilpolisiloxanoGC-5 GC-5MS GC-5MSUI-60 a 325/350HP-5, DB-5, VF-5MS, Rtx-5, Rxi-5, SP-5, ZB-5HP-5MS, DB-5MS, CP-Sil 8CB MS, VF-5MS, Rtx-5MS SP-5MS, ZB-5MS
G2825% fenil-75% metilpolisiloxanoGC-35MS40 a 320/340DB-35, DB-35MS, HP-35, Rtx-35, ZB-35, VF-35
G3220% fenilmetil-80% dimetilpolisiloxanoGC-35MS40 a 320/340DB-35, DB-35MS, HP-35, Rtx-35, ZB-35, VF-35
G35Polietilenglicol y diéster de nitrotereftalatoGC-FFAP40 a 260/280HP-FFAP, DB-FFAP, Rxt-Stabilwa-DA, CP-FFAP
G361% vinilo5% fenilmetilpolisiloxanoGC-5 GC-5MS GC-5MSUI-60 a 325/350HP-5, DB-5, VF-5MS, Rtx-5, Rxi-5, SP-5, ZB-5HP-5MS, DB-5MS, CP-Sil 8CB MS, VF-5MS, Rtx-5MS SP-5MS, ZB-5MS
G38Fase G1 más inhibidor de colasGC-1, GC-1MS-60 a 325/350HP-1, DB-1, VF-1, Rtx-1, Rxi-1, SP-1, ZB-1HP-1MS, DB-1MS, CP-Sil 5CB MS, VF-1MS, Rtx-1MS, Rxi-1MS
G39Polietilenglicol peso molecular promedio 1500GC-INOWAX40 a 260/280HP-Innowax, DB-Wax, DB-Waxer, CP-Wax 52, VF-WaxRxt-Stabilwax, Rtx-Wax, Omega-Wax
G41Fenilmetildimetilsilicona (10% sustituida con fenilo)GC-5 GC-5MS GC-5MSUI-60 a 325/350HP-5, DB-5, VF-5MS, Rtx-5, Rxi-5, SP-5, ZB-5HP-5MS, DB-5MS, CP-Sil 8CB MS, VF-5MS, Rtx-5MS, Rxi-5MS, SP-5MS, ZB-5MS
G4235% difenil65% dimetilvinilsiloxanoGC-35MS40 a 320/340DB-35, DB-35MS, HP-35, Rtx-35, ZB-35, VF-35
G436% cianopropilfenilo94% dimetilpolisiloxanoGC-1301 GC-624GC-VMS Purga-20 a 280/300DB-1301, CP-1301, VF-1301, Rtx-1301DB-624, DB-VRX, Rtx-624, Rtx-VMS, DB 502.2, VOCCol
G45Divinilbenceno etilenglicol dimetacrilatoGC-PLOT U-80 a 190/200HP-PLOT U, CP-Porapak U
G4614% cianopropilfenilo 86% metilpolisiloxanoGC-1701 GC-1701MS-20 a 280/300DB-1701, Rtx-1701, CP-Sil 19CB, VF-1701

avatar de autor
Biovanix
Biovanix Technology Co., Ltd. es una empresa especializada en biotecnología. Basándonos en nuestra experiencia fundamental en cromatografía líquida, hemos evolucionado estratégicamente hasta convertirnos en un proveedor integral de soluciones integradas que abarcan todo el ciclo de vida de la investigación, el análisis y la producción.

Comparte:

Más entradas

Designación ASTM para columnas GC

ASTM Designation For GC Column ASTM Designation Testing Method Method Title Recommended GC Columns D1945 GC Standard test method for the analysis of natural gas GC-PLOT MoleSieve, 15mx0.53mmx50μmGC-PLOT Q, 15mx0.53mmx30μm D1946 GC Standard test method for the analysis of reformed gas GC-PLOT MoleSieve, 15mx0.53mmx50μmGC-PLOT Q, 15mx0.53mmx30μm D1983 GLC of methyl ether Standard practice for measuring volatile organic

Informe de pruebas comparativas de la columna de afinidad para HPLC Prosep Protein A

Informe de Prueba Comparativa Para Análisis de mAb Columna HPLC Columnas: POR*S A, Columna Prosep Protein A Muestras: mAb, Proteína de Fusión, Proteína de Fusión sin Fc Preparación de Muestras Instrumento: Agilent 1260(DAD) Columna: SS de 2.1 mm × 30 mm; SS AbSolut A de 2.0 mm × 30 mm Muestra: Blanco (MPA) Estándares de Muestra: mAb, Proteína de Fusión, Proteína de Fusión sin Fc Imágenes de Prueba Conclusión Prosep Protein A y POR*S A