ISO Certified Manufacturer
Colonnes HPLC préemballées de précision pour des performances de séparation inégalées
High-Performance Liquid Chromatography (HPLC) columns are essential tools in modern analytical chemistry, widely used in pharmaceutical development, biomedical research, food safety testing, and environmental monitoring. HPLC columns achieve the efficient separation of complex mixtures by exploiting the differences in the distribution of solutes between the stationary phase and the mobile phase.
10,000
2.1–50
pH 2–12
20+
Technical Advantages
Engineered for Reproducibility, High Pressure Resistance & Superior Peak Resolution
Every Biovanix HPLC column is designed to deliver consistent, high-quality separations across a wide range of analytical conditions.
Types de phases stationnaires
Common stationary phases include silica, polymers, and chemically modified materials such as C18, C8, NH₂, etc. Different stationary phases are suitable for the separation of compounds with varying polarities.
Taille des particules et taille des pores
Particle sizes typically range from 1.8 µm to 10 µm, while pore sizes vary depending on the application, such as 100 Å, 200 Å, and 300 Å. Smaller particles can enhance separation efficiency but may require higher operating pressures.
Longueur et diamètre intérieur de la colonne
The selection of column length and inner diameter depends on the separation requirements. Longer columns generally provide higher separation efficiency.
Stabilité du pH
Some HPLC columns can operate stably over a broad pH range (e.g., pH 2-12), enabling flexible method development with aggressive mobile phases.
Catalogue des produits
Comprehensive HPLC Column Portfolio
Explore our full range of prepacked chromatography columns organized by application category. Click any product to learn more.
Applications
Trusted Across Industries
From drug development to environmental protection, Biovanix HPLC columns deliver reliable performance where it matters most.
Développement pharmaceutique
Utilisé pour la séparation, la purification et le contrôle de la qualité des composants des médicaments afin de garantir la sécurité et l'efficacité des produits pharmaceutiques.
Recherche biomédicale
Analyse des biomolécules (telles que les protéines et les peptides) et des métabolites pour soutenir la recherche en sciences de la vie.
Tests de sécurité alimentaire
Détecte les substances nocives telles que les additifs et les résidus de pesticides dans les aliments.
Surveillance de l'environnement
Contrôle des polluants organiques et des résidus de pesticides dans l'eau et le sol.
Selection Guide
How to Choose the Right HPLC Column
Selecting the optimal column dimension and stationary phase is critical for achieving the best separation results.
Colonne HIC | |||||
Colonne HbA1C | |||||
|
|
| |||
| Colonne amide |
|
|
| Colonne Ghost Peak |
En fonction de l'échelle et/ou de l'efficacité de la séparation requise, le tableau ci-dessous peut vous aider à choisir une colonne dont le diamètre intérieur (D.I.) et la longueur sont les plus appropriés à vos besoins.
Quelle est la longueur de colonne la mieux adaptée à mes besoins ?
- Si vous voulez maximiser la vitesse de votre application → 20 mm à 75 mm
- Si vous souhaitez un équilibre entre résolution et vitesse → 100 mm
- Si vous souhaitez la meilleure résolution possible → 150 mm
- Également disponible en dimensions analytiques et semi-prep.
Les colonnes USP (United States Pharmacopeia) sont des colonnes de chromatographie liquide à haute performance (HPLC) conçues pour répondre aux normes strictes établies par l'USP, garantissant la cohérence, la fiabilité et la conformité des procédures analytiques. Ces colonnes sont largement utilisées dans les applications pharmaceutiques, environnementales et de sécurité alimentaire pour fournir des résultats précis et reproductibles.
Why Biovanix
Why Choose Biovanix HPLC Columns?
Every column is engineered and manufactured to the highest standards, backed by our commitment to quality and technical support.
01
Stabilité à haute pression
Withstands up to 10 000 psi for UHPLC applications
Materials: 316L stainless steel or biocompatible PEEK
02
Résolution de crête exceptionnelle
Mirror-polished inner surface (Ra ≤0.2 μm) minimizes band broadening, delivering sharp, well-defined peaks for precise quantification.
03
Options personnalisables
Dimensions de la colonne : 2,1-50 mm ID | 20-500 mm longueur
Packing materials: C18, C8, HILIC, ion exchange, affinity resins
04
Large gamme de pH
Compatible with aggressive mobile phases across a broad pH range, enabling flexible method development for diverse analytes.
05
Conception à faible volume mort
Ensures minimal sample loss and high reproducibility, critical for trace-level analysis and quantitative accuracy.
Need Custom Specifications?
Our engineering team can tailor column dimensions, stationary phases, and end fittings to your exact requirements.
FAQ
Frequently Asked Questions
Everything you need to know about Biovanix prepacked HPLC columns.
What are prepacked HPLC columns and how do they work?
What types of HPLC columns does Biovanix offer?
- Reversed-Phase Columns — C18, C18H, C18L, C18AQ, C18BS, C8, C4-300, Phenyl
- Normal-Phase Columns — SiO₂, NH₂, CN, Diol, Amide
- Small-Molecule Columns — HILIC, Ion Exchange (SCX/SAX), Sugar Analysis
- Biological Columns — SEC (SEC-120/150/300/500/1000), HIC, DNA
- Specialty Columns — Chiral (8 types), Protein A, HbA1c
- Consommables — SS/PEEK column tubing, guard columns, inline filters, frits, fittings
What is the maximum operating pressure for Biovanix HPLC columns?
| Taille des particules | Max. Pression |
|---|---|
| 10 μm | 4,000 psi |
| 5 μm | 5,000 psi |
| 3 μm | 6,000 psi |
| SEC (3 μm) | 2,500 psi |
| SEC (5 μm) | 1 500 psi |
| UHPLC applications | Up to 10,000 psi |
Temperature limits: 60 °C for reversed-phase columns; 40 °C for SEC columns.
Can I customize HPLC column dimensions and packing materials?
- Inner diameter: 2.1–50 mm (10 standard sizes); non-standard sizes available upon request.
- Column length: 20–500 mm (8 standard lengths); custom lengths accepted.
- Packing materials: C18, C8, Phenyl, NH₂, CN, Diol, Bare Silica and more (particle sizes 3–50 μm; pore sizes 100/120/300 Å). Special bonded phases are available upon request.
- Matériel: 316L stainless steel or PEEK tubing; multiple frit types; custom end fittings and seals.
Are Biovanix HPLC columns suitable for pharmaceutical quality control?
- Columns carry recognized USP codes (L1, L3, L7, L8, L9, L10, L11, L14), enabling direct compliance with pharmacopeial methods.
- Ultra-pure silica with metal ions < 20 ppm ensures minimal peak tailing for basic compounds.
- Proprietary bonding chemistry with deep endcapping delivers low silanol activity and excellent batch-to-batch reproducibility.
- pH stability from 2–8 (up to 1–12 for C18BS) covers diverse mobile phase conditions.
- Manufacturing follows ISO 9001 quality standards.
- Applications explicitly include drug substance characterization, impurity profiling, dissolution testing, and content uniformity analysis.
How do I select the right HPLC column for my application?
- Hydrophobic compounds → C18 / C8 (reversed-phase)
- Aromatic compounds → Phenyl
- Polar compounds → HILIC / Amide
- Sugars → Sugar-10H / NH₂
- Proteins/antibodies → SEC-300 / C4-300
- Enantiomers → Chiral columns
- Analytical QC: 2.1–4.6 mm ID × 100–250 mm length
- Semi-preparative: 7.8–10 mm ID
- Preparative: 20–50 mm ID
- 3 μm: highest resolution (pharmacopeial methods)
- 5 μm: optimal balance (most common)
- 10 μm: low pressure, scalable to preparative
- 100 Å: small molecules (< 3 kDa)
- 300 Å: peptides and proteins
- SEC series: size-based separation of biomolecules
Ready to Optimize Your Chromatography?
Get detailed pricing, technical specifications, and custom column consultation from our experts.